8910DP42V14 SQUARE D, 8910DP42V14 Datasheet - Page 10

CONTACTOR, DPST, 24VAC, 40A, PANEL

8910DP42V14

Manufacturer Part Number
8910DP42V14
Description
CONTACTOR, DPST, 24VAC, 40A, PANEL
Manufacturer
SQUARE D
Type
DPr
Datasheets

Specifications of 8910DP42V14

No. Of Poles
2
Contact Configuration
DPST
Relay Mounting
Panel
Coil Voltage Vac Nom
24V
Relay Terminals
Screw
Contact Voltage Ac Nom
600V
Contact Current Max
40A
Mounting Type
Panel
Contact Form
DPST-NO
Current, Rating
40 A
Function
Contactor
Horse Power Rating
2 @ 115 VAC, 5 @ 230 VAC
Number Of Poles
2
Relay Type
Electro Mechanical
Voltage, Coil
24 VAC
Enclosure Type
Open
Maximum Voltage Rating
600 VAC
Phase
1-Phase
Operating Voltage
600VAC
Switching Power Ac1
5hp
Switching Current Ac1
50A
Switching Current Ac3
40A
Load Current Inductive
40A
Load Current Resistive
50A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Class 8911 — Types DPS and H through M
10
© 1998 Square D All Rights Reserved
Cross Reference Existing/Replacement Class 8911
Miscellaneous Parts and Kits
Class 8911 Replacement Coils
Coil Table
Auxiliary Contacts For Type DPS Starters
Ratings – Overload Contacts and Auxiliary Contacts
k Type DPS 4-Pole starter not available. Suggest 3-Pole device with auxiliary contact.
f Use for 20 to 40 amp starters; for larger sizes, contact your local Square D office.
t Replace asterisk with Voltage Code from the Coil Table shown below.
c Auxiliary contacts are available factory installed. Consult local Square D Field Sales Office.
9998 SO1
9999 SO4
9999 R20 & R21
9999 D10, D01,
D11 & D20
Full Load
Amperes
20-40 A
50-60 A
75-90 A
Device
Start-Stop push button kitf
Hand-Off-Auto selector switch kitf
Standard N.C. overload relay contact
N.C. and N.O. isolated overload relay alarm contacts
Overload relay jumper strap
Voltage, 60 Hz
208-240
120
277
480
600
Existing Device
24
Description
1 N.O.
1 N.C.
1 N.O./1 N.C.
2 N.O.
MO33
MG33
MO43
MG43
HO33
HG33
KO33
KG33
KO43
KG43
LO33
LG33
JO33
JG33
120 or Less
120-600
Volts
Poles
AC
2 & 3
2 & 3
2 & 3
Description
30 Amps
3600 VA
Make
Class 9998
Voltage, 50 Hz
Pilot Duty – AC Only
(35% Power Factor)
Type
DA1t
DA2t
DA3t
110
220
440
550
...
24
c
Carry & Break
3 Amps
Replacement Device
360 VA
Inrush
109
214
Class 9999
56
DPSO13
DPSG13
DPSO23
DPSG23
DPSO33
DPSG33
DPSO43
DPSG43
DPSO53
DPSG53
Volt Amperes
D10
D01
D11
D20
k
k
k
k
Voltage Code
Current Rating
Continuous
Class & Type
V14
V02
V09
V04
V06
V07
8911 DPB1
8911 DSS1
9998 SO1
9999 SO4
9998 SO31
5 Amps
5 Amps
Sealed
5/98
10
19
6

Related parts for 8910DP42V14