PIC18F2480-E/ML Microchip Technology, PIC18F2480-E/ML Datasheet - Page 347

IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,LLCC,28PIN,PLASTIC

PIC18F2480-E/ML

Manufacturer Part Number
PIC18F2480-E/ML
Description
IC,MICROCONTROLLER,8-BIT,PIC CPU,CMOS,LLCC,28PIN,PLASTIC
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18F2480-E/ML

Rohs Compliant
YES
Core Processor
PIC
Core Size
8-Bit
Speed
25MHz
Connectivity
CAN, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
25
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Processor Series
PIC18F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
768 B
Interface Type
SPI, I2C, MSSP, EUSART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
25
Number Of Timers
4
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000, ICE4000, DM163011, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F2480-E/ML
Manufacturer:
MICROCHIP
Quantity:
1 001
24.15.6.1
An overflow condition occurs when the MAB has
assembled a valid received message (the message
meets the criteria of the acceptance filters) and the
receive buffer associated with the filter is not available
for loading of a new message. The associated
RXBnOVFL bit in the COMSTAT register will be set to
indicate the overflow condition. This bit must be cleared
by the MCU.
24.15.6.2
The receive error counter has reached the MCU
warning limit of 96.
© 2009 Microchip Technology Inc.
Receiver Overflow
Receiver Warning
PIC18F2480/2580/4480/4580
24.15.6.3
The transmit error counter has reached the MCU
warning limit of 96.
24.15.6.4
This will occur when the device has gone to the error-
passive state because the receive error counter is
greater or equal to 128.
24.15.6.5
This will occur when the device has gone to the error-
passive state because the transmit error counter is
greater or equal to 128.
24.15.6.6
The transmit error counter has exceeded 255 and the
device has gone to bus-off state.
Receiver Bus Passive
Transmitter Bus Passive
Transmitter Warning
Bus-Off
DS39637D-page 347