LM82CIMQA National Semiconductor, LM82CIMQA Datasheet - Page 8

no-image

LM82CIMQA

Manufacturer Part Number
LM82CIMQA
Description
IC,SSOP,16PIN
Manufacturer
National Semiconductor
Datasheets

Specifications of LM82CIMQA

Rohs Compliant
NO

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM82CIMQA
Manufacturer:
national
Quantity:
21
Part Number:
LM82CIMQA
Manufacturer:
NS
Quantity:
1 000
Part Number:
LM82CIMQA
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM82CIMQA
Quantity:
300
Part Number:
LM82CIMQAX/NOPB
Manufacturer:
NS/TI
Quantity:
1 200
www.national.com
Logic Electrical Characteristics
Note 7: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 8: The Temperature Error will vary less than
Note 9: Quiescent current will not increase substantially with an active SMBus.
Note 10: This specification is provided only to indicate how often temperature data is updated. The LM82 can be read at any time without regard to conversion state
(and will yield last conversion result).
Note 11: Default values set at power up.
Note 12: Holding the SMBData and/or SMBCLK lines Low for a time interval greater than t
state of an SMBus communication (SMBCLK and SMBData set High).
1.0 Functional Description
The LM82 temperature sensor incorporates a band-gap type
temperature sensor using a Local or Remote diode and an
8-bit ADC (Delta-Sigma Analog-to-Digital Converter). The
LM82 is compatible with the serial SMBus and I
interfaces. Digital comparators compare Local (LT) and Re-
mote (RT) temperature readings to user-programmable set-
points (LHS, RHS, and TCS). Activation of the INT output
indicates that a comparison is greater than the limit preset in
a HIGH register. The T_CRIT setpoint (TCS) interacts with
all the temperature readings. Activation of the T_CRIT_A
output indicates that any or all of the temperature readings
have exceed the T_CRIT setpoint.
1.1 CONVERSION SEQUENCE
The LM82 converts its own temperature as well as a remote
diode temperature in the following sequence:
1. Local Temperature (LT)
FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
FIGURE 3. Printed Circuit Board Used for Thermal Resistance Specifications
±
1.0˚C for a variation in V
2
C two wire
(Continued)
CC
8
of 3V to 3.6V from the nominal of 3.3V.
10129724
2. Remote Diode (RT)
This round robin sequence takes approximately 480 ms to
complete.
1.2 INT OUTPUT and T_HIGH LIMITS
Each temperature reading (LT, and RT) is associated with a
T_HIGH setpoint register (LHS, RHS). At the end of a tem-
perature reading a digital comparison determines whether
that reading has exceeded its HIGH setpoint. If the tempera-
ture reading is greater than the HIGH setpoint, a bit is set in
one of the Status Registers, to indicate which temperature
reading, and the INT output is activated.
Local and remote temperature diodes are sampled in se-
quence by the A/D converter. The INT output and the Status
Register flags are updated at the completion of a conversion,
which occurs approximately 60 ms after a temperature diode
is sampled. INT is deactivated when the Status Register,
containing the set bit, is read and a temperature reading is
TIMEOUT
will cause the LM82 to reset SMBData and SMBCLK to the IDLE
10129705

Related parts for LM82CIMQA