DSPIC30F6010AT-20E/PT Microchip Technology, DSPIC30F6010AT-20E/PT Datasheet - Page 99

no-image

DSPIC30F6010AT-20E/PT

Manufacturer Part Number
DSPIC30F6010AT-20E/PT
Description
IC,DSP,16-BIT,CMOS,TQFP,80PIN,PLASTIC
Manufacturer
Microchip Technology
Series
dsPIC™ 30Fr

Specifications of DSPIC30F6010AT-20E/PT

Rohs Compliant
YES
Core Processor
dsPIC
Core Size
16-Bit
Speed
20 MIPS
Connectivity
CAN, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, Motor Control PWM, QEI, POR, PWM, WDT
Number Of I /o
68
Program Memory Size
144KB (48K x 24)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 5.5 V
Data Converters
A/D 16x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
80-TFQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
DM300019 - BOARD DEMO DSPICDEM 80L STARTERXLT80PT3 - SOCKET TRAN ICE 80MQFP/TQFPAC164320 - MODULE SKT MPLAB PM3 80TQFPAC30F007 - MODULE SKT FOR DSPIC30F 80TQFPDM300020 - BOARD DEV DSPICDEM MC1 MOTORCTRL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSPIC30F6010AT-20E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
15.4
Center-aligned PWM signals are produced by the
module when the PWM time base is configured in an
Up/Down Counting mode (see Figure 15-3).
The PWM compare output is driven to the active state
when the value of the Duty Cycle register matches the
value of PTMR and the PWM time base is counting
downwards (PTDIR = 1). The PWM compare output is
driven to the inactive state when the PWM time base is
counting upwards (PTDIR = 0) and the value in the
PTMR register matches the duty cycle value.
If the value in a particular Duty Cycle register is zero,
then the output on the corresponding PWM pin will be
inactive for the entire PWM period. In addition, the
output on the PWM pin will be active for the entire PWM
period if the value in the Duty Cycle register is equal to
the value held in the PTPER register.
FIGURE 15-3:
15.5
There are four 16-bit Special Function Registers
(PDC1, PDC2, PDC3 and PDC4) used to specify duty
cycle values for the PWM module.
The value in each Duty Cycle register determines the
amount of time that the PWM output is in the active
state. The Duty Cycle registers are 16-bits wide. The
LSb of a Duty Cycle register determines whether the
PWM edge occurs in the beginning. Thus, the PWM
resolution is effectively doubled.
© 2008 Microchip Technology Inc.
PTPER
Duty
Cycle
0
Center-Aligned PWM
PWM Duty Cycle Comparison
Units
Period/2
CENTER-ALIGNED PWM
Period
PTMR
Value
dsPIC30F6010A/6015
15.5.1
The
double-buffered to allow glitchless updates of the PWM
outputs. For each duty cycle, there is a Duty Cycle
register that is accessible by the user and a second
Duty Cycle register that holds the actual compare value
used in the present PWM period.
For edge-aligned PWM output, a new duty cycle value
will be updated whenever a match with the PTPER
register occurs and PTMR is reset. The contents of the
duty cycle buffers are automatically loaded into the
Duty Cycle registers when the PWM time base is dis-
abled (PTEN = 0) and the UDIS bit is cleared in
PWMCON2.
When the PWM time base is in the Up/Down Counting
mode, new duty cycle values are updated when the
value of the PTMR register is zero and the PWM time
base begins to count upwards. The contents of the duty
cycle buffers are automatically loaded into the Duty
Cycle registers when the PWM time base is disabled
(PTEN = 0).
When the PWM time base is in the Up/Down Counting
mode with double updates, new duty cycle values are
updated when the value of the PTMR register is zero,
and when the value of the PTMR register matches the
value in the PTPER register. The contents of the duty
cycle buffers are automatically loaded into the Duty
Cycle registers when the PWM time base is disabled
(PTEN = 0).
15.5.2
When the Immediate Update Enable bit is set (IUE = 1),
any write to the Duty Cycle registers will update the
new duty cycle value immediately. This feature gives
the option to the user to allow immediate updates of the
active PWM Duty Cycle registers instead of waiting for
the end of the current time base period. System
stability is improved in closed loop servo applications
by reducing the delay between system observation and
the issuance of system corrective commands when
immediate updates are enabled (IUE = 1).
If the PWM output is active at the time the new duty
cycle is written and the new duty cycle is less than the
current time base value, the PWM pulse width will be
shortened. If the PWM output is active at the time the
new duty cycle is written and the new duty cycle is
greater than the current time base value, the PWM
pulse width will be lengthened.
If the PWM output is inactive at the time the new duty
cycle is written and the new duty cycle is greater than
the current time base value, the PWM output will
become active immediately and will remain active for
the new written duty cycle value.
four
DUTY CYCLE REGISTER BUFFERS
DUTY CYCLE IMMEDIATE
UPDATES
PWM
Duty
Cycle
DS70150D-page 99
registers
are