AS5046ASSU austriamicrosystems, AS5046ASSU Datasheet - Page 12

no-image

AS5046ASSU

Manufacturer Part Number
AS5046ASSU
Description
IC, MAGNETIC ROTARY ENCODER 12BIT SSOP16
Manufacturer
austriamicrosystems
Type
Magnetic Rotary Encoderr
Datasheet

Specifications of AS5046ASSU

Ic Function
Encoder IC
Supply Voltage Range
3V To 3.6V, 4.5V To 5.5V
Operating Temperature Range
-40°C To +125°C
Digital Ic Case Style
SSOP
No. Of Pins
16
Filter Terminals
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AS5046 Programmable 360° Magnetic Angle Encoder – Preliminary Data Sheet
9.2
The Hall Sensor Front End allows configuration of each Hall Sensor. Each sensor can be disabled or connected to either the
SIN or COS signal bus. Additionally, each sensor can be inverted for differential measurement.
Each Hall Sensor is selected through a device address for the type identifier 0001,
address 000 selects Hall Sensor H0 (see Figure 8)
address 111 selects Hall Sensor H7 (see Figure 8)
Note: If the magnet is placed like shown in Figure 8 the encoder reading will be of zero.
For each Hall Sensor, the corresponding Front End contains 8 bits
TestEN:
SenseEN:
COS_EN:
SIN_EN:
INV:
PD:
Note: When enabling or disabling individual Hall elements to the SIN- and COS- signal buses it is recommended
to allow several milliseconds (typ. 5ms) of dwelling time until the signal is stable and eventual offsets are
compensated.
Revision 1.1
Addr. 000…111
Type ID: 0001
Hall Sensor Front End (Type ID: 0001)
always set to 0
set to 1 for enabled Hall Elements, set to 0 for disabled Hall Elements
set to 0 for disabled Hall Elements, set to 1 if this Hall Element should be added to the COS signal bus. It
is also possible to enable multiple Hall sensors to this bus
set to 0 for disabled Hall Elements, set to 1 if this Hall Element should be added to the SIN signal bus. It
is also possible to enable multiple Hall sensors to this bus
set to 1 if the Hall Element should be inverted for differential measurement. set to 0 if the Hall Element
should not be inverted
set to 0 for normal operation, set to 1 if the Hall Sensor should be powered down.
TestEN
SenseEN
Figure 8: Location of Hall Elements on chip (top view)
NC
www.austriamicrosystems.com
NC
Byte1
COS_EN
SIN_EN
INV
PD
Page 12 of 33

Related parts for AS5046ASSU