B6TS-04LT-002 DEFAULT Omron, B6TS-04LT-002 DEFAULT Datasheet - Page 4

SENSOR, CAP TOUCH, 4 CH, SMD, SOP20

B6TS-04LT-002 DEFAULT

Manufacturer Part Number
B6TS-04LT-002 DEFAULT
Description
SENSOR, CAP TOUCH, 4 CH, SMD, SOP20
Manufacturer
Omron
Datasheet

Specifications of B6TS-04LT-002 DEFAULT

Supply Current
5mA
Supply Voltage Range
3V To 5.5V
Sensor Case Style
SOP
No. Of Pins
20
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC (15-Dec-2010)
Operating Temperature Max
85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Recommended operating conditions
Note: Unless otherwise specified, V
Electrical characteristics
Note: 1. Unless otherwise specified, V
Necessary timing conditions
Note: 1. Unless otherwise specified, V
4
V
V
V
I
I
V
V
I
I
I
t
t
t
t
t
T
t
t
t
T
T
T
OH
OL
IH
IL
CC
c(SCK)
w(SCKH)
w(SCKL)
d(SO)
h(SO)
h(SI)
w(BD)
w(CD)
w(CHG)
w(RESET)
OH
OL
su(SI)
su(SETUP)
dd
IH
IL
Designation
Designation
Designation
2. The period following receipt of the EEPROM write command in setup mode until the data write finishes.
2. This is the time period when the condition that CHG pulse width is at its minimum in the serial communication mode of normal measure-
3. The delay time for the mode shift between normal measurement mode and setup mode.
ment mode is set.
(CHG pin function is set to output at the end of every measurement [CHG bit = 0 with MODE command] and the sleep time is set to zero
[SLP command value = 0]).
Capacitive Touch Sensing ICs
Supply voltage
High input voltage
Low input voltage
High output voltage
Low output voltage
High output voltage
Low input voltage
High input voltage
Low input voltage
Supply voltage
Number of times of EEPROM write
EEPROM write time
EEPROM data retention period
Serial communication clock cycle time
Serial communication clock high pulse width
Serial communication clock low pulse width
Serial communication output delay time
Serial communication output hold time
Serial communication input setup time
Serial communication input hold time
Serial communication byte to byte interval
Serial communication command reception interval
CHG pulse width
Mode shift delay time
Reset pulse width
dd
= 4.5 – 5.5V, T
Item
dd
dd
= 4.5 – 5.5V, T
= 4.5 – 5.5V, T
Item
Item
OPR
B6TS
= -20 – 85° C.
OPR
OPR
= -20 – 85° C.
= -20 – 85° C.
I
I
V
V
Normal measurement mode
T
V
(Note 2)
T
OH
OL
OPR
OPR
I
I
dd
= 5V
= 0V
= 5mA
= -5mA
= 5V, T
= 0 – 60° C
= 55° C
Condition
OPR
(Note 2)
(Note 3)
Condition
= 25° C
Condition
Minimum
Minimum
V
0.8V
10000
dd
4.5
20
0
-2.0
dd
Rated value
Rated value
Minimum
Standard
Standard
8650
100
100
265
500
0.3
35
90
70
85
4
0
Rated value
Maximum
Maximum
Maximum
0.2V
150
5.5
V
V
2.0
80
-5
-5
5
5
dd
dd
dd
V
V
V
mA
mA
V
V
µA
µA
mA
Times
S
Years
nS
nS
nS
nS
nS
nS
nS
µS
µS
µS
µS
µS
Unit
Unit
Unit