LM2594M-ADJ National Semiconductor, LM2594M-ADJ Datasheet - Page 25
LM2594M-ADJ
Manufacturer Part Number
LM2594M-ADJ
Description
SWITCHING REG 0.5A ADJ, SMD, 2594
Manufacturer
National Semiconductor
Datasheet
1.LM2594M-5.0.pdf
(28 pages)
Specifications of LM2594M-ADJ
Primary Input Voltage
40V
No. Of Outputs
1
Output Voltage
37V
Output Current
500mA
Voltage Regulator Case Style
SOIC
No. Of Pins
8
Operating Temperature Range
-40°C To +125°C
Svhc
No SVHC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LM2594M-ADJ
Manufacturer:
NS
Quantity:
258
Part Number:
LM2594M-ADJ
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM2594M-ADJ/NOPB
Manufacturer:
National Semiconductor
Quantity:
1 940
Company:
Part Number:
LM2594M-ADJ/NOPB
Manufacturer:
NS/TI
Quantity:
70
Application Information
put reaches its nominal output voltage. The actual time de-
pends on the output voltage and the size of the output
capacitor. Input power sources that are current limited or
sources that can not deliver these currents without getting
loaded down, may not work correctly. Because of the rela-
tively high startup currents required by the inverting topology,
the delayed startup feature (C1, R
25 is recommended. By delaying the regulator startup, the
input capacitor is allowed to charge up to a higher voltage
before the switcher begins operating. A portion of the high in-
put current needed for startup is now supplied by the input
capacitor (C
pacitor can be made much larger than normal.
IN
). For severe start up conditions, the input ca-
FIGURE 28. Inverting Regulator Ground Referenced Shutdown using Opto Device
FIGURE 27. Inverting Regulator Ground Referenced Shutdown
1
and R
(Continued)
2
) shown in Figure
25
INVERTING REGULATOR SHUTDOWN METHODS
To use the ON /OFF pin in a standard buck configuration is
simple, pull it below 1.3V (
turn regulator ON, pull it above 1.3V to shut the regulator
OFF. With the inverting configuration, some level shifting is
required, because the ground pin of the regulator is no
longer at ground, but is now setting at the negative output
voltage level. Two different shutdown methods for inverting
regulators are shown in Figure 27 and Figure 28 .
DS012439-42
@
25˚C, referenced to ground) to
DS012439-43
www.national.com