Specifications of S29GL064A10TFIR20
Memory Size
64Mbit
Memory Configuration
64K X 16
Ic Interface Type
Parallel
Access Time
100ns
Memory Case Style
TSOP
No. Of Pins
48
Page/burst Read Access
25ns
Supply Voltage Max
3.6V
Sector Type
Uniform
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
- Current page: 45 of 79
- Download datasheet (2Mb)
November 16, 2007 S29GL-N_01_09
Notes
1. When Sector Address is specified, any address in the selected sector is acceptable. However, when loading Write-Buffer address
2. DQ7 may change simultaneously with DQ5. Therefore, DQ7 should be verified.
3. If this flowchart location was reached because DQ5= 1, then the device FAILED. If this flowchart location was reached because DQ1= 1,
4. See
locations with data, all addresses must fall within the selected Write-Buffer Page.
then the Write to Buffer operation was ABORTED. In either case, the proper reset command must be written before the device can begin
another operation. If DQ1= 1, write the Write-Buffer-Programming-Abort-Reset command. if DQ5= 1, write the Reset command.
Table 10.1 on page 51
DQ1 = 1?
and
D a t a
No
Yes
(Note 1)
Table 10.3 on page 53
(Note 3)
Figure 10.1 Write Buffer Programming Operation
(Note 2)
S29GL-N MirrorBit
Yes
S h e e t
No
Write next address/data pair
Write number of addresses
to program minus 1(WC)
Write first address/data
Write program buffer to
address = Last Loaded
Read DQ7 - DQ0 with
Write “Write to Buffer”
Last Loaded Address
flash sector address
and Sector Address
Read DQ7 - DQ0 at
Buffer Operation?
Sector Address
FAIL or ABORT
command and
WC = WC - 1
Abort Write to
DQ7 = Data?
DQ7 = Data?
DQ5 = 1?
Address
WC = 0 ?
for command sequences required for write buffer programming.
®
Flash Family
Yes
No
No
No
No
Yes
Yes
Yes
Part of “Write to Buffer”
Command Sequence
Write to buffer ABORTED.
Must write “Write-to-buffer
Abort Reset” command
Write to a different
sequence to return
sector address
to read mode.
PASS
45
Related parts for S29GL064A10TFIR20
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Flash 3V 32Mb Float Gate two address 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 64Mb Float Gate two address 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 64Mb Float Gate standard config 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 1 Gb Mirrorbit highest address120ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 256Mb Mirrorbit highest address110ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 64Mb Float Gate highest address 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 512Mb Mirrorbit lowest address100ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 32Mb Float Gate highest address 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 64Mb Float Gate highest address 90s
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 1 Gb Mirrorbit highest address110ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 256Mb Mirrorbit lowest address110ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 512Mb Mirrorbit highest address110ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 128Mb Mirrorbit lowest address110ns
Manufacturer:
Spansion Inc.
Datasheet:
Part Number:
Description:
Flash 3V 64Mb Float Gate standard config 70s
Manufacturer:
Spansion Inc.
Part Number:
Description:
IC, FLASH, 1MBIT, 70NS, LCC-32
Manufacturer:
Spansion Inc.
Datasheet: