BQ2040SN-C408 BENCHMARQ, BQ2040SN-C408 Datasheet - Page 8

no-image

BQ2040SN-C408

Manufacturer Part Number
BQ2040SN-C408
Description
BATTERY CHARGE MONITOR, SMD, 2040
Manufacturer
BENCHMARQ
Datasheet

Specifications of BQ2040SN-C408

Battery Management Function
Charger, Status Monitor
Battery Type
Li-Ion / NiCd / NiMH
Supply Voltage Range
3V To 6.5V
Battery Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
0°C
Interface Type
2-Wire, Serial

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BQ2040SN-C408
Manufacturer:
TIBB
Quantity:
391
Part Number:
BQ2040SN-C408
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
BQ2040SN-C408TR
Manufacturer:
ST
Quantity:
38
Part Number:
BQ2040SN-C408TR
Manufacturer:
TI/德州仪器
Quantity:
20 000
bq2040
Charge Counting
Charge activity is detected based on a positive voltage
on the SR input. If charge activity is detected, the
bq2040 increments RM at a rate proportional to V
and, if enabled, activates an LED display. Charge ac-
tions increment the RM after compensation for charge
state and temperature.
The bq2040 determines charge activity sustained at a
continuous rate equivalent to V
charge equates to sustained charge activity
greater than 10 mAh. Once a valid charge is detected,
charge threshold counting continues until V
low V
scribed in the Digital Magnitude Filter section.
Discharge Counting
All discharge counts where V
register to decrement and the DCR to increment. V
is a programmable threshold as described in the Digital
Magnitude Filter section.
Self-Discharge Estimation
The bq2040 continuously decrements RM and incre-
ments DCR for self-discharge based on time and temper-
ature provided that the discharge flag in BatteryStatus
is set (charge not detected). The bq2040 self-discharge
estimation rate is programmed in EE 0x4f and can be
set from 0 to 25% per day for 20–30°C. This rate approx-
imately doubles for every 10°C increase until the tem-
perature is
the temperature is < 10 C.
Charge Control
The bq2040 supports SBS charge control by broadcast-
ing the ChargingCurrent and the ChargingVoltage to
the Smart Charger address. The bq2040 broadcasts
charging commands every 10 seconds; the broadcasts
can be disabled by writing bit 14 of BatteryMode to 1.
On reset, the initial charging current broadcast to the
charger is set to the value programmed in EE 0x08-
0x09. The bq2040 updates the value used in the charg-
ing current broadcasts based on the battery’s state of
charge, voltage, and temperature.
The bq2040 internal charge control is compatible with
nickel-based and Li-Ion chemistries. The bq2040 uses
current taper detection for Li-Ion primary charge termi-
nation and T/ t for nickel based primary charge termi-
nation. The bq2040 also provides a number of safety
terminations based on battery capacity, voltage, and
temperature.
SRD
. V
70 C or halves every 10 C decrease until
SRD
is a programmable threshold as de-
SRO
SRO
< -V
> +V
SRD
cause the RM
SRD
SRO
. A valid
falls be-
SRO
SRD
8
Current Taper
For Li-Ion charge control, the ChargingVoltage must be
set to the desired pack voltage during the constant volt-
age charge phase. The bq2040 detects a current taper
termination when it measures the pack voltage to be
within 128mV of the requested charging voltage and
when the AverageCurrent is less than the programmed
threshold in EE 0x38—0x39 and non-zero for at least
100s.
The T/ t used by the bq2040 is programmable in both
the temperature step (1.6 C–4.6 C) and time step (20
seconds–320seconds). Typical settings for 1 C/min in-
clude 2 C over 120 seconds and 3 C over 180 seconds.
Longer times are required for increased slope resolution.
In addition to the T/ t timer, there is a hold-off timer,
which starts when the battery is being charged at more
than 255mA and the temperature is above 25 C. Until
this timer expires, T/ t is suspended. If the tempera-
ture falls below 25 C, or if charging current falls below
255mA, the timer is reset and restarts only if these con-
ditions are once again within range. The hold-off time is
programmed in EE 0x63.
Charge Termination
Once the bq2040 detects a valid charge termination, the
Fully_Charged, Terminate_Charge_Alarm, and the
Over_Charged_Alarm bits are set in BatteryStatus, and
the requested charge current is set to zero. Once the
te rmi na ti ng
nate_Charge_Alarm and the Over_Charged_Alarm are
cleared, and the requested charging current is set to the
maintenance rate. The bq2040 requests the mainte-
nance rate until RM falls below the amount determined
by the programmable full- charge percentage. Once this
occurs, the Fully_Charged bit is cleared, and the re-
quested charge current and voltage are set to the
fast-charge rate.
Bit 4 (CC) in FLAGS2 determines whether RM is modi-
fied after a T/ t or current taper termination occurs. If
CC = 1, RM may be set from 0 to 100% of the FullChar-
geCapacity as defined in EE 0x4c. If RM is below the
full-charge percentage, RM is set to the full-charge per-
centage of FCC. If RM is above the full-charge percent-
age, RM is not modified.
T
T/ t
t
is set by the formula:
[
(lower nibble of EE 0x4a) 2 + 16 / 10
[
320
con dit i ons
(
EE 0x62
T
t
)
ce as e,
20)]
]
the
o
s
C
Term i-