CIRCULAR CONN, RCPT, SIZE 18, 10POS, BOX

97-4102A-18-19S

Manufacturer Part Number
97-4102A-18-19S
Description
CIRCULAR CONN, RCPT, SIZE 18, 10POS, BOX
Manufacturer
Amphenol Industrial Operations
Type
Panel Socketr
Datasheets

Specifications of 97-4102A-18-19S

Connector Body Material
Aluminum Alloy
Gender
Receptacle
Contact Gender
Socket
Connector Mounting
Box
Connector Shell Size
18
Insert Arrangement
18-19
Connector Type
Circular Industrial
Agency Approvals
UL/CSA
Angle
Straight
Application
Commercial
Brand/series
97 Series
Class
A
Contact Configuration
10#16
Contact Plating
Silver
Contact Type
Socket
Current, Rating
13 A
Diameter, Mounting Hole
0.12 "
Finish, Housing
Clear Cadmium
Flammability Rating
UL94-V0
Housing Type
Metal
Material, Housing
Aluminum Alloy
Mating Type
Threaded
Mount Method
Front
Mounting Type
Chassis
Number Of Contacts
10
Primary Type
5015 Commercial
Shell Size
18
Special Features
Rear Release
Strain Relief
Solid
Termination
Crimp
Voltage, Rating
500/700 VAC/VDC
Wire, Awg
16
Standard Shell Finish
Clear Chromate Over Cadmium Plate
Inserts
Molded 94V-O UL Rated Material
Contacts
Copper Alloy Formed, Silver Plated; Gold Plating Also Available
Wire Sizes
12-30 AWG, UL File #LR69183
Operating Temperature Range
–55°C to +125°C
Amphenol Aerospace operates Quality Systems that are Certified to ISO-9001 and AS-9100 by third party
Registrars.
Table of Contents
Amphenol
Guide to Selecting a Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Amphenol
Amphenol
Special Purpose Connectors
97 Series Accessories
Additional Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41, 42
Sales Office Listing
Design Characteristics, Customer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Insert Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 5
Contact Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
Alternate Insert Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Receptacle Shell Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Solid Shell Plug Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Split Shell Plug Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Weight Reference Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18
How to Order. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Design Characteristics, Customer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Specifications and Insert Availability, Alternate Insert Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Contact Arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23
Receptacle Shell Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Solid Shell Plug Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Split Shell Plug Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
How to Order. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Crimp Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Crimp Contact Information cont., Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Potting Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Box Type Plugs, Small Flange Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ECG Connector, Convenience Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Cable Clamps, Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33,34
Protection Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35, 36
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Conduit Box Connector, Conduit Coupling Nuts, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Sealing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Dummy Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
®
®
®
97 Series Standard Cylindrical Connectors – General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
97 Series Connectors with Solder Contacts
97 Series Connectors with Rear Release Crimp Contacts
Page

Related parts for 97-4102A-18-19S