SI3050-E-FT

Manufacturer Part Number
SI3050-E-FT
Description
IC VOICE DAA GCI/PCM/SPI 20TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3050-E-FT

Package / Case
20-TSSOP (0.173", 4.40mm Width)
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Function
Data Access Arrangement (DAA)
Interface
PCM, Serial, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Product
RF / Wireless
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
Supply Current
8.5 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3050-E-FT
Manufacturer:
Silicon Labs
Quantity:
1 794
Part Number:
SI3050-E-FTR
Manufacturer:
SILICONI/矽睿科技
Quantity:
20 000
Si3050 + Si3018/19
Register 37. PCM Receive Start Count—High Byte
Reset settings = 0000_0000
Register 38. TX Gain Control 2
Reset settings = 0000_0000
86
Bit
7:2
1:0
Bit
7:5
3:0
4
Name
Name
Type
Type
Bit
Bit
TXG2[3:0] Transmit Gain 2.
Reserved Read returns zero.
Reserved
Name
RXS[1:0]
TGA2
Name
D7
D7
Transmit Gain or Attenuation 2.
0 = Incrementing the TXG2[3:0] bits results in gaining up the transmit path.
1 = Incrementing the TXG2[3:0] bits results in attenuating the transmit path.
Each bit increment represents 1 dB of gain or attenuation, up to a maximum of +12 dB and
–15 dB respectively.
For example:
TGA2
X
0
0
0
1
1
1
PCM Receive Start Count.
PCM Receive Start Count equals the number of PCLKs following FSYNC before data
reception begins.
Read returns zero.
D6
D6
TXG2[3:0]
0000
0001
11xx
0001
1111
:
:
D5
D5
Rev. 1.31
0 dB gain or attenuation is applied to the transmit path.
1 dB gain is applied to the transmit path.
12 dB gain is applied to the transmit path.
1 dB attenuation is applied to the transmit path.
15 dB attenuation is applied to the transmit path.
Result
TGA2
R/W
D4
D4
Function
Function
D3
D3
D2
D2
TXG2[3:0]
R/W
D1
D1
RXS[1:0]
R/W
D0
D0

Related parts for SI3050-E-FT