447-K-H-FN-125A E-T-A, 447-K-H-FN-125A Datasheet

CIRCUIT BREAKER THERM 125A PNLMT

447-K-H-FN-125A

Manufacturer Part Number
447-K-H-FN-125A
Description
CIRCUIT BREAKER THERM 125A PNLMT
Manufacturer
E-T-A
Series
447r
Datasheet

Specifications of 447-K-H-FN-125A

Breaker Type
Thermal
Voltage
28VDC
Current - Trip (it)
125A
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
447-K-H-FN-125AMP
447KHFN-125A
447KHFN-125A
447KHFN-125AMP
Q1504821C
Single pole thermal-magnetic circuit breakers with tease-free, trip-free,
press-to-reset snap action mechanism and special dual button manual
release which avoids the danger of unintended disconnection (M-type
TM CBE to EN 60934). Surface mounted, compact design available
with fast acting, standard and delayed switching characteristics.
Options include auxiliary contact and remote electrical disconnection.
Heavy duty vehicles, battery systems, process control.
Type No.
446
447
449
447 - K - H - FN - ... - ... - 400 A
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Type 446
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
single pole base mounting, fast characteristic curve
single pole base mounting, medium delay characteristic curve
single pole base mounting, delayed characteristic curve
Terminal design, mounting
K
S
screw terminals M12, insertion nuts M8
screw terminals M12, insertion nuts 5/16-18
Manual release
H
Current
rating (A)
30
40
50
60
70
80
90
100
125
150
170
200
225
250
300
350
400
standard
Version
N
FN
general application (type 446 only)
general application (types 447 and 449 only)
Auxiliary contacts (optional)
Si
High Performance Thermal-Magnetic Circuit Breakers 446/447/449
2 electrically separate auxiliary contacts
with screw terminals M3.5 and
blade terminals DIN 46244-C-MS-S
Remote trip (optional for types 447 and 449)
FA12
FA24
Internal
resistance (Ω)
0.006
0.0048
0.0038
0.0028
0.0025
0.0023
0.0019
0.0016
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.00
DC 12 V coil voltage
DC 24 V coil voltage
Current ratings
30...400 A
100...400 A
125...500 A
ordering example
type 446
type 447
type 449
Current
rating (A)
Type 447
100
125
160
225
300
400
Type 449
125
160
225
315
350
400
500
only with 50 % ON duty
Internal
resistance (Ω)
< 0.002
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
< 0.001
www.e-t-a.com
Dielectric strength
(IEC 60664 and 60664A)
Degree of protection
without aux. contacts:
Humidity
Voltage rating
Current rating range
Auxiliary circuit
Electrical remote disconnection (-FA)
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
(IEC 60529/DIN 40050)
Vibration
Shock
with auxiliary contacts:
Corrosion
Mass
Authority
Type 446:
Type 447:
Type 449:
Technical data
Approvals
operating voltage
operating current
max. pulse time
switching time
operating area
main circuit to
auxiliary contacts
without aux. contacts:
with auxiliary contacts:
UL
UL
QPL Sweden
UL
VG 95345, part 15
446-...
cn
DC 28 V
type 446: 30...400 A
type 447: 100...400 A
type 449: 125...500 A
10 A
DC 12 V or DC 24 V
approx. 18 A or 12 A
10 ms < t
< 20 ms
1,000 operations at I
2,000 operations mechanical
-55...+75 °C (-67...+167 °F)
rated impulse
withstand voltage
1.5 kV
test voltage
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
10,000 A
operating area IP40
terminal area IP00
to VG 95210, sheet 19,
IEC 60068-2-6, test Fc:
10 g (56-500 Hz), ± 0.76 mm (10-55 Hz)
4 g (56-500 Hz), ± 0.30 mm (10-56 Hz)
to VG 95210, sheet 28,
IEC 60068-2-27, test Ea:
50 g (11 ms)
20 g (11 ms)
96 hours at 5 % salt mist
to VG 95210, sheet 2,
IEC 60068-2-11, test Ka
240 hours at 95 % RH
to VG 95210, sheet 7,
IEC 60068-2-3, test C
approx. 850 g
Voltage ratings
DC 28 V
DC 28 V
DC 28 V
DC 28 V
DC 28 V
447-...
ON
< 20 ms / t
449-...
Current ratings
30...400 A
100...400 A
125...400 A
125...350 A
125...500 A
N
pollution
degree
3
OFF
> 10 s
4 - 31
4

Related parts for 447-K-H-FN-125A

447-K-H-FN-125A Summary of contents

Page 1

... A type 447 125...500 A type 449 447 - ... - ... - 400 A ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. Standard current ratings and typical internal resistance values ...

Page 2

... High Performance Thermal-Magnetic Circuit Breakers 446/447/449 Dimensions 60 2.36 ø26 1.02 N/C 4/5 106 4.17 N/O 6/7 35 1.38 100 3.94 170 6.69 140 5.51 current rating EIN ON AUS OFF 43.5 11 .433 1.71 blade terminal DIN 46244-C-MS-S flat head screw ISO 1580-M3.5x5 tightening torque max. 0.55 Nm This is a metric design and millimeter dimensions take precedence ( mm ) 447-… ...

Related keywords