NOVEC CONTACT CLEANER 12 OZ 3M, NOVEC CONTACT CLEANER 12 OZ Datasheet - Page 6

Chemicals Contact Cleaner 11oz

NOVEC CONTACT CLEANER 12 OZ

Manufacturer Part Number
NOVEC CONTACT CLEANER 12 OZ
Description
Chemicals Contact Cleaner 11oz
Manufacturer
3M

Specifications of NOVEC CONTACT CLEANER 12 OZ

Product
Cleaners & Degreasers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
5113571699
Hazardous Decomposition: Decomposition of this product at temperatures above 300 degrees C can form perfluoroisobutylene
(PFIB), but PFIB will only accumulate with continuous exposure to excessive heat in a sealed vessel. The formation rate for PFIB is
about 1000 times less than the rate for primary thermal decomposition products such as HF. During normal use conditions, no health
hazard is associated with the use of this material due to PFIB exposure.
ECOTOXICOLOGICAL INFORMATION
CHEMICAL FATE INFORMATION
Waste Disposal Method: To reclaim or return, contact your 3M sales representative.
Incinerate in an industrial or commercial facility in the presence of a combustible material. As a disposal alternative, dispose of waste
product in a facility permitted to accept chemical waste. Combustion products will include HF. Facility must be capable of handling
halogenated materials.
Facility must be capable of handling aerosol cans. Dispose of empty product containers in a sanitary landfill.
EPA Hazardous Waste Number (RCRA): Not regulated
ID Number(s):
98-0212-3293-3, 98-0212-3329-5, 98-0212-3337-8, 98-0212-3459-0
_________________________________________________________________________________________________
MATERIAL SAFETY DATA SHEET Novec™ Contact Cleaner
SECTION 13: DISPOSAL CONSIDERATIONS
SECTION 14:TRANSPORT INFORMATION
SECTION 15: REGULATORY INFORMATION
SECTION 11: TOXICOLOGICAL INFORMATION
Test Organism
Fathead Minnow, Pimephales promelas
Green algae, Selenastrum capricornutum
Water flea, Daphnia magna
Test Type
SECTION 12: ECOLOGICAL INFORMATION
Please contact the address listed on the first page of the MSDS for Toxicological Information on this material and/or its
components.
Since regulations vary, consult applicable regulations or authorities before disposal.
For Transport Information, please visit http://3M.com/Transportinfo or call 1-800-364-3577 or 651-737-6501.
Perfluoroisobutylene (PFIB)
96 hours Lethal Concentration 50%
96 hours Inhibitory Concentration 50%
48 hours Effect Concentration 50%
See Section 3.3
Test Type
Result
heat
heat
At Elevated Temperatures - extreme condition of
05/25/11
Result
> 7.9 mg/l
> 8.9 mg/l
> 10 mg/l
Protocol
Page 6 of 9