00043 Simpson, 00043 Datasheet - Page 13

no-image

00043

Manufacturer Part Number
00043
Description
Test Probes PROBE SET THREADED W
Manufacturer
Simpson
Datasheet

Specifications of 00043

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Designed specifically to measure hazardous "Leakage Currents" or "Touch Currents"
which may appear when a person touches the conductive surface of electrical or
electronic equipment. The 228 is designed in accordance with IEC990, ANSI and UL
guidelines.
Model 228 Special Purpose AC/DC Milliameter
• True RMS Readings
• Reads in Measurement Indication Units (MIU) up to .005 MIU
• Output Allows Measurement of Peak Current in Non-Sinusoidal Wave Forms
• Let-Go, Reaction, and Burn Hazard Response Networks
• Detects dangerous AC & DC Leakage currents
• Includes Test Leads, Alligator Clips, Batteries and Manual
Specifications
Leakage Tester
228 Leakage Current Tester
GENERAL
Equivalent network component values:
Equivalent measuring instrument load:
Ranges:
Current accuracy:
Meter measurement method:
Meter frequency response:
Output sensitivity:
Output accuracy:
Output frequency response:
Voltmeter range:
Voltmeter accuracy: DC to 1 Hz
Voltmeter frequency response:
Power requirements:
Physical:
Environmental:
Maximum operating range:
Ordering Information
DC to 1 Hz
2Hz to 19Hz (Accuracy not supported)
20 Hz to 200 KHz
200 KHz to 1 MHz
DC to 50Hz
50 Hz to 100 KHz
100 kHz to 1 MHz
2Hz to 19Hz (Accuracy not supported)
20 Hz to 1KHz
Catalog No.
40027
ACCESSORIES
Test Leads w/Screw-On Alligator Clips
Case, Black Padded Nylon Carrying
Additional accessories are on pages 22-24.
Specifications subject to change without notice.
Response Network
1 M - 10pF
0.3, 1, 3, 10 M.I.U.
Full scale meter indication equals 1V RMS (Measured with a 1 M , 12 pF load)
27°C
2% F.S.
2% F.S.
2.5% of reading
Reaction
2° C, 70% non condensing relative humidity. Outside this range derate by 10% per °C
Complies with values specified in IEC 990 (excluding fuse)
(Relative to ANSI C101-1992 or UL-1459 2nd edition)
(Relative to ANSI C101-1992 or UL-1459 2nd edition)
7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input
11
228 Leakage Current Tester
Pointer shall track within 5% of peak
Pointer shall track within 5% of peak
2% of reading @ 60 Hz
Catalog No.
Response Network
00125
00834
1 M - 62 pF
0.3, 1, 3, 10 M.I.U.
+2% /-3% of reading
0-300 V (AC or DC)
DC to 1 KHz
0° to 40° C
2% F.S. @ 60 Hz
2.5% of F.S.
2.5% F.S.
2% of reading
5% of reading
3% F.S. @ 60 Hz (Add
(2) 9V (NEDA 1604A) batteries
True RMS
Let-Go
Optional carrying case
includes convenient
storage pouch for test
leads and Operators
Manual.
1% for every additional 100Hz)
Unweighted Burn Hazard
Response Network
1 M
0-100 mA RMS
2% of reading
- 1 pF
2% F.S.
5% F.S.

Related parts for 00043