4010-01-B Bourns Inc., 4010-01-B Datasheet

Test Accessories - Other SURGE TEST KIT WCASE

4010-01-B

Manufacturer Part Number
4010-01-B
Description
Test Accessories - Other SURGE TEST KIT WCASE
Manufacturer
Bourns Inc.
Datasheet

Specifications of 4010-01-B

Display Type
Digital
Features
Lightweight, LCD display, 10 V to 1000 V test range, auto shutoff
Measured Components
Clamping Voltage, DC Breakdown Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Bourns
breakdown voltage of most surge protective devices. The 4010-01 is suitable for testing gas tubes, carbon gaps, MOVs, Zener and
avalanche diodes and thyristor devices, both as components and as complete protectors.
The 4010-01 is a true slow-rise tester because it does not use a pulse transformer. It contains unique test circuitry and a precise 1 mA
detector. As soon as 1 mA is conducted through clamping type devices, such as MOVs and avalanche diodes, the control circuits
removes the test voltage from the output terminals and displays the clamping voltage on the meter. A low energy capacitive circuit will
discharge through crowbar type protectors, such as gas tubes and carbon blocks, and trigger the detector. The breakdown voltage
will be displayed and the test voltage removed.
Internal switches for ramp speed and discharge circuit type are accessed by removing the back cover. They are to be set for the
intended application: 200 V/s for laboratory tests or QC type approvals; 1000 V/s for high-speed testing or sorting. The IEEE
discharge circuit permits gas tubes to conduct in the arc mode, while the ITU circuit generally allows only glow currents to fl ow.
Pushing the test button applies a linear ramp to the device under test. Sensing circuitry automatically terminates the test when either
the dc breakdown or 1 mA clamping voltage is reached. The test value is maintained on the LCD display until the test button is
released.
Open Circuit Voltage Rate of Rise ......................................................................................................... 200 V/s or 1000 V/s
Maximum Output Voltage ...................................................................................................................... 1000 V
Useable Measuring Range .................................................................................................................... 10-1000 V
Test Current for Clamping Devices ........................................................................................................ 1 mA ±10 %
Test Current for Crowbar Devices ......................................................................................................... >1 A
Operating Temperature .......................................................................................................................... 0 to +50 °C
Storage Temperature ............................................................................................................................. -10 to +60 °C
Measurement Accuracy ........................................................................................................................ 0.5 %
Power Source ........................................................................................................................................ 3 lithium batteries -
Battery Life
Shipping Weight .................................................................................................................................... 2 lbs.
Warranty ................................................................................................................................................ 2 years
Notes:
• For P-type thyristor protectors, breakdown voltage V
• For N-type thyristor protectors, breakover voltage V
Description
Operation
Specifi cations
Functional Block Diagram
200 V/s ............................................................................................................................................. Up to 10,000 tests
1000 V/s ........................................................................................................................................... Up to 50,000 tests
actual V
measure V
®
4010-01 Surge Protector Test Set is a hand-held, battery-operated tester designed to measure the clamping voltage and dc
BO
Z
.
.
Start Circuit
Power
and
Shut
Off
Features
4010-01 - Surge Protector Test Set
Lightweight, hand-held design
Easy-to-read LCD display
Simple operation
High accuracy peak reading circuit
Wide 10-1000 V test range
Precise auto-sensing shutoff
Linear Ramp
Low Voltage
Generator
BO
BO
is higher than the zener voltage V
occurs at the device zener voltage V
DC Converter
Peak Voltage
High Voltage
Circuit and
Meter
DC to
Customers should verify actual device performance in their specifi c applications.
Storage/Discharge
Current Limiting
and Energy
Network
Z
Applications
Suitable for testing:
. For these devices, the tester will
Gas tubes
Carbon gaps
MOVs
Zener and avalanche diodes
Thyristor devices
Finished product
Z
Voltage Shutoff
Sense for High
. Therefore, the tester will measure
1 mA Current
Specifi cations are subject to change without notice.
NEMA type 5024LC
Under Test
to Device
Output

4010-01-B Summary of contents

Page 1

... The 4010- true slow-rise tester because it does not use a pulse transformer. It contains unique test circuitry and a precise 1 mA detector. As soon conducted through clamping type devices, such as MOVs and avalanche diodes, the control circuits removes the test voltage from the output terminals and displays the clamping voltage on the meter ...

Page 2

... How To Order Part No. Accessories Included 4010-01 ............... No Accessories 4010-01-A ........... Nylon Carrying Case 4010-01-B ........... Nylon Case, 48-inch Leads w/Alligator Clips (Suitable for Testing A.C. Arresters on Site) 4010-01-C ........... Nylon Case, P/N 72288 and 72289 Gas Tube Adapters 4010-01-D ........... Nylon Case, P/N 72291 5-Pin Module Adapter REV ...