H7CX-AWD1-N DC12-24 AC24 Omron, H7CX-AWD1-N DC12-24 AC24 Datasheet - Page 33

Tachometers CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr

H7CX-AWD1-N DC12-24 AC24

Manufacturer Part Number
H7CX-AWD1-N DC12-24 AC24
Description
Tachometers CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr
Manufacturer
Omron
Type
1 or 2 State, Total and Preset Counterbatch, Dual/Twin Counterr
Datasheet

Specifications of H7CX-AWD1-N DC12-24 AC24

Frequency Response
50 Hz
Product
Panel Mount Tachometer
Voltage
12 VDC to 24 VDC, 24 VAC
Display Type
6 Digit
Accuracy
+/- 0.1 %
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXAWD1NDC1224/AC24
Operation in Run Mode
Tachometer Operation
*1 Measurement value 1 for the 2-input input mode.
*2 Measurement value 2 for the 2-input input mode.
*3 Peak/bottom hold enabled
• Set each digit using the individual U Keys.
Displayed when the input mode is not 2 inputs.
Peak hold value
Bottom hold value
*3
Measurement value
Measurement value 1
Comparison value 1
Measurement value 2
Comparison value 2
*1
*2
• Measurement value
• Comparison value 1/Comparison value 2
Displays the currently measured value.
Set comparison value 1 and comparison value 2.
The measurement value is compared to
comparison value 1 and comparison value 2 and
output is made according to the selected output
mode.
Displayed for the 2-input input mode.
Peak hold value 1
Bottom hold value 1
Peak hold value 2
Bottom hold value 2
• Peak/bottom hold value
• Peak/bottom hold value 2
Note: The held values will be initialized when
The peak (maximum) and bottom (minimum)
Peaks (maximums) 1 and 2 and bottoms
values are displayed after counting starts.
(minimums) 1 and 2 are displayed after counting
starts.
the Reset Key (Hold Key) or reset 1 input
is turned OFF while peak/bottom hold
values 1 and 2 are being displayed. (The
reset 2 input operates in the same way if
the input mode is set to 2-input mode.)
H7CX-A@-N
Tachometer
33