Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
50 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Accuracy
2 %
Current, Primary
50 A
Current, Ratio
50:5
Current, Secondary
5 A
Diameter, Inside
1.56 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
50 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Transformer Type
Donut
Turns Ratio
10:1
Input Current
50A
Transformer Mounting
Panel
Current Rating
50A
Current Ratio
50
Leaded Process Compatible
No
Mounting Type
Donut
Output Current
5A
Peak Reflow Compatible (260 C)
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
• Wide Variety of Control, Alarm, and Limit
• Calibration Not Affected by Steel Panel
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Dimensions
Use
Mounting
Proof
4 - 1/2”-Model 3344AIXA & 3324AIXA
1
=
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
Movement:
Suspension:
Tracking:
Repeatability:
Shielding:
Response Time:
Overload (1 sec.):
Overload (Continuous):
Dial:
Case:
Voltage Drop:
Pointer:
Scale Length:
Net Weight:
Control Point(s)
Adjustments:
Switching:
Differential:
Auto/Manual Reset:
Contacts/Output Relay:
Frequency Response:
Power:
Operating Temperature:
Circuit-to-Ground
Voltage:
NOTE:
3 - 1/2”-Model 3343AIXA & 3323AIXA
AC: ±3% of full scale; DC: ±2% F.S.
Annular, self-shielding
Pivot and jewel
±3%
Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA
AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S.
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Sealed metal, plastic window
50mV
Black, knife-edge
4.05" (103.0mm)
17oz (0.48kg)
Single, high limit, 0-100% of arc; double, low limit 0-
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Within 1% of indication
“On,” “Off” difference is within 0.5% of F.S.
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
50-1000Hz
108-132 VAC, 50-400Hz
+41°F to 122°F (5°C to +50°C)
250V rms maximum
DC meters meet ANSI specification C-39.1
29
B