06713 Simpson, 06713 Datasheet - Page 9

Analog Panel Meters SHUNT 100 AMP 50 MV

06713

Manufacturer Part Number
06713
Description
Analog Panel Meters SHUNT 100 AMP 50 MV
Manufacturer
Simpson
Type
Current Shuntsr
Datasheets

Specifications of 06713

Equipment Type
Portable Shunt
Range
0 - 100
Accuracy
±1%
Current, Rating
100 A
Dimensions
6.00 in. L x 1.25 in. W x 1.60 in. D
Includes
5 ft. Leads
Resistance
0.065 Ohms
Screw Size
10-32
Voltage, Output
50 mV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• 3/64 DIN Temperature Indicator
• Jumper-selectable input type and ºC/ºF
• Screw terminal connectors for easy installation
• Unique mounting bracket allows for stacking
Dimensions - M235, M245 & M240
indication
of multiple meters
2.66”
.89”
2.71”
Specifications
DISPLAY
Type
Height
Display resolution
Overrange indication (T/C or
mV)
Open or faulty input connection
Uncalibrated instrument
Polarity
POWER REQUIREMENTS
AC Voltage
Power Consumption
INPUTS
Thermocouple
Millivolt
Lead Resistance Effect
RTD
Lead Resistance Effect
Temperature Coefficient
Input Impedance:
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Warmup time
A TO D CONVERSION
Technique
Rate
NOISE REJECTION
NMRR
CMRR
MECHANICAL
Bezel
Depth
Panel cutout
Weight
Case Material
Input Type
RTD Pt100
K T/C
J T/C
(4-wire)
mV
Temperature Range
-148 to 2498°F
-100 to 1200°C
-148 to 2192°F
-100 to 1370°C
-70 to 70mV
-100 to 850°C
-148 to 1562°F
7-segment red LED
0.56" (14.2mm)
0.1° from -99.9° to 999.9°; 1.0° below -
100° or above 1000°; 0.1mV for mV
indication
The left-most digit shows 1: "1" (other
digits are blank)
Display will flash continuously “INFO
FAIL CALB REQD” upon application of
power.
Automatic, with "-" indication; "+" indica-
tion implied
85-250VAC @50-60Hz
2VA
J, K
±70mV (uncompensated for temperature)
-13µV/100 max.
Platinum 100 Ohm (.00385 alpha)
4-wire -.26°C/100V max.
2- and 3-wire 1°/.29 max.
±0.2°C / °C
22M
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
Less than 20 minutes
12 Bit Successive Approximation (SAR)
10 samples per second
60dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min
0.94" x 2.83"
2.36"
0.89" x 2.71"
3.5oz (99.2g)
94-0,UL-rated, glass-filled thermoplastic
"----"
±(0.1% rdg +1.5°C)
±(0.1% rdg +1.5°C)
±(0.1% rdg +0.1mV)
±(0.1% rdg +2.7°F)
±(0.1% rdg +2.7°F)
±(0.2% rdg +1.5°C)
±(0.2% rdg +2.7°F)
Accuracy @25ºC
more >>