FLUKE-175 Fluke, FLUKE-175 Datasheet - Page 3

Digital Multimeters TRMS MULTIMETER

FLUKE-175

Manufacturer Part Number
FLUKE-175
Description
Digital Multimeters TRMS MULTIMETER
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-175

Accuracy
+/- 0.15 %
Resistance Range
50 M Ohms
Capacitance Range
9999 uF
Frequency
2 Hz to 50 KHz
Equipment Type
Digital Multimeters
Display Count
6000
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1564551
Page 3 of 3, Document #2155
170 Series True-rms DMMs
Extended Specifications
©2000 Fluke Corporation
Rev. A-11/2000
Detailed Specifications
Function
AC Volts
DC mV
DC Volts
Continuity
Ohms
Diode test
Capacitance
AC Amps
(True-rms)
(45 Hz to 1 kHz)
DC Amps
Hz
(AC- or DC-
coupled,
V or A
Temperature
MIN MAX AVG
1. All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
3. In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % for all models.
4. In mA and A ranges, frequency measurement is specified to 30 kHz.
5. Frequency < 10 kHz are not specified in 600 mV AC, 60 mA AC, and 6 A AC ranges.
Function Overload Protection
Volts AC
Volts DC 1000 V RMS or DC
Ohms
Diode test 1000V RMS or DC
1. 10
7
V-Hz maximum.
4, 5
2
input ) 99.99 kHz
1000 V RMS or DC
1000V RMS or DC
Range
600.0 mV
6.000V
60.00V
600.0V
1000V
600.0 mV
6.000V
60.00V
600.0V
1000V
600Ω
600.0Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
50.00 MΩ
2.400V
1000 nF
10.00 µF
100.0 µF
9999 µF
60.00 mA
400.0 mA
(600 mA for 18 hrs)
6.000A
10.00A
(20A for 30s)
60.00 mA
400.0 mA
(600 mA for 18 hrs)
6.000A
10.00A
(20A for 30s)
99.99 Hz
999.9 Hz
9.999 kHz
-40 °C to +400 °C
-40 °F to +752 °F
For DC functions, accuracy is the specified of the measurement function ± 12 counts for changes
longer than 275 ms in duration.
For AC functions, accuracy is the specified of the measurement function ± 40 counts for changes
longer than 1.2 s in duration.
1
3
1
Input Impedance
(Nominal)
> 10 MΩ < 100 pF
> 10 MΩ <100 pF
Open Circuit Test
Voltage
< 1.5 V DC
2.4 to 3.0 V DC
Resolution
0.1 mV
0.001V
0.01V
0.1V
1V
0.1 mV
0.001V
0.01V
0.01V
1V
1Ω
0.1Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.001V
1 nF
0.01 µF
0.1 µF
1 µF
0.01 mA
0.1 mA
0.001A
0.01A
0.01 mA
0.1 mA
0.001A
0.01A
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 °C
0.1 °F
Common Mode Rejection Ratio Normal Mode Rejection
(1 kΩ Unbalanced)
> 60 dB @ DC, 50 or 60 Hz
>120 dB @ DC, 50 or 60 Hz
Full Scale Voltage To:
6.0 MΩ
< 600 mV DC
2.4 V DC
Accuracy ± ( [ % of Reading ] + [ Counts ] )
Model 175
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
0.15 % + 2
0.15 % + 2
0.15 % + 2
Meter beeps at < 25 Ω, beeper turns off at > 250 Ω;
detects opens or shorts of 250 ms or longer.
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
1 % + 2
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.5 % + 3
1.0 % + 3
0.1 % + 1
NA
50 MΩ
< 1.5 V DC
Model 177
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
0.09 % + 2
0.09 % + 2
0.1 % + 2
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.5 % + 3
1.0 % + 3
0.1 % + 1
NA
> 60 dB @ 50 Hz or 60 Hz
Short Circuit Current
< 500 µA
< 1.2 mA typical
Model 179
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
0.09 % + 2
0.09 % + 2
0.1 % + 2
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.5 % + 3
1.0 % + 3
0.1 % + 1
1 % + 1.0 °C
1 % + 1.8 °F
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
U.S.A. (800) 443-5853 or
Fax (425) 446-5116
Europe (31 40) 2 675 200 or
Fax (31 40) 2 675 222
Canada (905) 890-7600 or
Fax (905) 890-6866
Other countries (425) 446-5500 or
Fax (425) 446-5116
Web access: http://www.fluke.com
©2001 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 3/2001
Printed on recycled paper.
up and running.