Specifications of 5XP-A

Accuracy
+/- 1 %
True Rms
No
Min / Max Hold
Yes
Resistance Range
200 Ohms to 20 M Ohms
Equipment Type
Compact Full-Purpose Digital Multimeter with VolTect Non-Contact Voltage Detector
Display Count
1999
Dmm Type
Handheld
Voltage Measuring Range Dc
200mV To 1000V
Voltage Measuring Range Ac
200mV To 750V
Current Measuring Range Dc
200µA To 200mA
Current Measuring Range Ac
200µA To 200mA
Battery Type
9V
Current, Range
200 uA, 2 mA, 20 mA, 200 mA
Display Type
LCD
Resistance, Range
200Ω, 2KΩ, 200KΩ, 2MΩ, 20MΩ
Voltage, Range, Ac
200 mV, 2 V, 20 V, 200 V, 750 V
Voltage, Range, Dc
200 mV, 2 V, 20 V, 200 V, 1000 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727851
5XP-A Digital Multimeter
General Specifications
Specifications
Voltage
Current
Resistance
Continuity
Amprobe® Test Tools
Display
Polarity
Overrange
Low Battery Indication
Measurement Rate
Operating Environment
Storage Temperature
Accuracy
Temperature Coefficient
Altitude
Power
Battery Life
Dimensions (H x W x D)
Weight
Warranty
Function
DC Volts
AC Volts (45 Hz to 500 Hz)
Resolution
Input Impedance
Overload Protection
DC Current
AC Current (45 Hz to 500 Hz)
Resolution
Input Protection
Burden Voltage
Resolution
Open Circuit Voltage
Overload Protection
Audible Indication
Response Time
Overload Protection
Ranges
Ranges
Ranges
Ranges
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
Automatic, positive implied, negative polarity indication
(OL) or (-OL) is displayed
The “M” is displayed when the battery voltage drops below the operating level
2.5 times per second, nominal
0 °C to 50 °C at <70 % R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
2000 m (6561.7 ft)
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
200 hours typical with carbon-zinc
155 mm x 72 mm x 32 mm (6.1 in x 2.8 in x 1.3 in)
Approx. 210 g (7.4 oz) including battery
One-year
Range
200 mV, 2 V, 20 V, 200 V, 1000 V
200 mV, 2 V, 20 V, 200 V, 750 V
100 μV
10 MW
200 mV: 1000 V DC or 750 V AC RMS (3 minutes)
All other ranges: 1000 V DC or 750 V AC RMS
200 μA, 2 mA, 20 mA, 200 mA
200 μA, 2 mA, 20 mA, 200 mA
0.1 μA
315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input
300 mV max. (1 V max. on 200 mA range)
200 W, 2 kW, 20 kW, 200 kW
2 MW
20 MW
100 mW
0.3 V DC typical, (3.0 V DC on 200 W range)
1000 V DC or 750 V AC RMS
75 W
100 ms
1000 V DC or 750 V AC RMS
± (1.0 % rdg + 1 dgt)
± (1.5 % rdg + 5 dgts)
± (1.5 % rdg + 1 dgt)
± (2.0 % rdg + 5 dgts)
± (1.0 % rdg + 4 dgts)
± (1.5 % rdg + 4 dgts)
± (2.0 % rdg + 5 dgts)
± 25 W
Accuracy