DMM4020 Tektronix, DMM4020 Datasheet

Digital Multimeters 5.5 DIGIT BENCH MULTIMETER

DMM4020

Manufacturer Part Number
DMM4020
Description
Digital Multimeters 5.5 DIGIT BENCH MULTIMETER
Manufacturer
Tektronix
Datasheet

Specifications of DMM4020

Accuracy
0.015 %
True Rms
Yes
Min / Max Hold
Yes
Peak Hold
Yes
Data Hold
Yes
Resistance Range
200 Ohms to 100 MOhms
Frequency
47 Hz to 440 Hz
Characteristic
Trigger Delay: 400 msTrigger Input: TTL LevelsTrigger Output: 5 V max
Current, Rating
200 μA to 10 A, 1 nA Resolution
Dimensions
3.46 × 8.56 × 11.7 (88 × 217 × 297) In. (mm)
Display Type
Vacuum Fluorescent Display, segment
Frequency Range
47 to 440 Hz
Includes
National Instrument's LabVIEW SignalExpress™ TE Limited Ed.
Interface
USB to RS-232
Power Consumption
15 VA peak (10 W average)
Resolution
5.5 Digit Resolution
Temperature, Operating
0 to 50 °C
Temperature, Storage
–40 to 70 °C
Voltage, Rating
200 mV to 1000 V, 10 μV Resolution
Warranty
3 Years
Weight
4.6 (2.1) Lb. (kg)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digital Multimeters
Tektronix DMM4020 Data Sheet
DMM4020
Features & Benefits
Key Performance Specifications
5.5 Digit Resolution
Basic VDC Accuracy of up to 0.015% (1 yr.)
200 mV to 1000 V Voltage Range, with up to 10 μV Resolution
200 μA to 10 A Current Range, with up to 1 nA Resolution
200 Ω to 100 MΩ Ohm Range, with up to 1 mΩ Resolution
CAT I 1000 V, CAT II 600 V
Available Functions and Features
Connectivity
3-year Warranty
Volts, Ohms, and Amps Measurements
Diode and Continuity Testing
Frequency Measurements
2×4 Ohms 4-wire Measurement Technique
Dedicated DC Leakage Current Measurements
Six Dedicated Buttons for Fast Access to Instrument Setups
Limit Compare Mode for Pass/Fail Testing
Front 2×4 Measurement Inputs
RS-232 on Rear Panel for Quick PC Connectivity
Includes USB to RS-232 Interface Adapter Cable
Includes National Instrument’s LabVIEW SignalExpress™ TE Limited
Edition for Connecting Your Bench

DMM4020 Summary of contents

Page 1

... Digital Multimeters Tektronix DMM4020 Data Sheet DMM4020 Features & Benefits Key Performance Specifications 5.5 Digit Resolution Basic VDC Accuracy 0.015% (1 yr.) 200 mV to 1000 V Voltage Range, with μV Resolution 200 μ Current Range, with Resolution 200 Ω to 100 MΩ Ohm Range, with mΩ Resolution ...

Page 2

... Typical multimeter measurements – volts, ohms, and amps – are made with a basic VDC accuracy 0.015%, ensuring you have the performance you need for your design. You can also use the DMM4020 to measure frequency, and to perform continuity and diode tests. This allows you to replace your counter, continuity tester, and DMM with one versatile instrument, saving bench space and cost ...

Page 3

... Signal Express acquiring data from Tektronix DMM4020 and DPO3052. Connect Your Bench for Intelligent Debug Easily capture, save, and analyze measurement results from your multimeter with the special Tektronix Edition of National Instrument’s LabVIEW SignalExpress™ software. Every DMM4020 multimeter ships with a free copy of the Limited Edition version of SignalExpress for basic instrument control, data logging, and analysis ...

Page 4

... Complies with MIL-PRF-28800F Class 3 Safety Complies with IEC 61010-1:2001, ANSI/ISA 61010-1 (S82.02.01):2004, UL 61010-1:2004, CAN/CSA C22.2 No. 61010.1:2004, CAT I 1000V / CAT II 600 V EMC Designed to comply with IEC 61326-1:1997+A1:1998+A2:2000 4 www.tektronix.com Triggering Characteristic Trigger Delay External Trigger Delay External Trigger Jitter Trigger Input Trigger Output Math Functions Min/max, relative, hold, compare, and dB functions in ...

Page 5

... Digital Multimeters — Tektronix DMM4020 Input Impedance Fast 10 μV >10 GΩ* 2 100 μV >10 GΩ* 2 1000 μV 10 MΩ ± MΩ ...

Page 6

... Hz – 20 kHz 20 kHz – 50 kHz 50 kHz – 100 kHz 750 – – 20 kHz 20 kHz – 50 kHz 50 kHz – 100 kHz * Uncertainty given as ±(% of reading + % of range www.tektronix.com Volts-Hertz product 7 Resolution Slow Medium 1 μV 10 μV 10 μV 100 μV 100 μV 1000 μV ...

Page 7

... Digital Multimeters — Tektronix DMM4020 Current Source Fast 0.01 Ω 0.8 mA 0.1 Ω 0 Ω 0. Ω 0.008 mA 100 Ω ...

Page 8

... A 1.99999 10.0000 A Accuracy Range 200 μ 200 Uncertainty given as ±(% of reading + % of range www.tektronix.com Resolution Slow Medium 0.001 μA 0.01 μA 0.01 μA 0.1 μA 0.1 μA 1 μA 1 μA 10 μA 10 μA 100 μA 100 μ Uncertainty days 1 year 23 ° ...

Page 9

... Accuracy Range Frequency kHz 200 kHz kHz kHz * Uncertainty given as ±(% of reading + % of range). 3 Digital Multimeters — Tektronix DMM4020 Resolution Slow Medium 0.1 μA 1 μA 1 μA 10 μA 10 μA 100 μA 100 μ Uncertainty days 23 °C ±5 °C 23 °C ±5 ° 0.05 1.25 + 0.06 ...

Page 10

... Test Current Response Time 100 S/s with audible tone Rate Fast Maximum Reading 199.99 Ω Resolution 0.01 Ω 10 www.tektronix.com Uncertainty 90 days 1 year 23 °C ±5 °C 23 °C ±5 °C 0.01 + 0.002 0.01 + 0.003 0.01 + 0.002 0.01 + 0.003 0.01 + 0.002 0.01 + 0.003 ...

Page 11

... Description DMM4020 5.5 Digit Multimeter DMM4020 Includes: Meter, TL710 test leads, line cord, spare line fuse, statement of cal practices, Warranty statement, Safety and Installation Guide, Connectivity Installation Manual, CD-ROM with user manual (English, French, Italian, German, Spanish, Simplified Chinese, Traditional Chinese, Korean, Russian, Japanese), RS-232 to USB Adapter Cable, National Instruments LabVIEW SignalExpress™ ...

Page 12

... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...