I310S Fluke, I310S Datasheet

Clamp Multimeters & Accessories AC/DC CURRENT CLAMP

I310S

Manufacturer Part Number
I310S
Description
Clamp Multimeters & Accessories AC/DC CURRENT CLAMP
Manufacturer
Fluke
Datasheet

Specifications of I310S

Bandwidth
20 kHz
Battery Life
30 hours
Connector Type
BNC-4MM
Impedance
10 kΩ
Jaw Opening
19 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2840309
i310s Current Probe
Electrical specifications
-
-
-
-
-
-
-
-
-
-
Safety standards
-
-
-
-
-
EMC Standards
-
i310s connects to oscilloscopes via safety BNC, to multimeters via BNC-4MM
adapter supplied
Dual range 30/300 A
Wide Bandwidth – 20kHz (-3dB)
Output Sensitivity of 10/1 mV / A
10 kΩ Load Impedance
Accuracy of +/- 1% of reading ± 50/300 mA
Maximum Jaw Conductor 19mm (0.75 in)
Battery Life – 30 hours with low battery indicator
Superior noise rejection for power electronics applications
Typical applications include invertors, switch mode power supplies, industrial
controllers requiring current measurement and/or waveform analysis,
automobile diagnostics.
BS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
300 V
Use of the probe on uninsulated conductors is limited to 300 V AC
DC and frequencies
below 1 kHz.
BS EN 61326 : 1998 +A1, A2, & A3
RMS
, Category III, Pollution Degree 2
The i310s current probe is based on Hall Effect technology
for use in measurement of both DC and AC current. The
i310s may be used in conjunction with oscilloscopes and
other suitable recording instruments for accurate non-
intrusive current measurement.
RMS
or