ACDC-100 Amprobe, ACDC-100 Datasheet - Page 2

Clamp Multimeters & Accessories AC/DC CLAMP-ON

ACDC-100

Manufacturer Part Number
ACDC-100
Description
Clamp Multimeters & Accessories AC/DC CLAMP-ON
Manufacturer
Amprobe
Datasheet

Specifications of ACDC-100

Accuracy
+/- 1.5 %
Frequency
40 Hz to 100 Hz
Maximum Ac Current
1000 A
True Rms
No
Voltage
600 V
Ranging
Auto, Manual
Display Count
4000
Features
Carrying case, test leads, batteries and user manual included
Dmm Type
Clamp
Voltage Measuring Range Dc
400mV To 600V
Voltage Measuring Range Ac
400mV To 600V
Current Measuring Range Dc
0A To 1000A
Current Measuring Range Ac
400A To 800A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2740452
1000A ACDC-100 AC/DC Clamp-On Multimeter
Electrical Specifications
Amprobe® Test Tools
Function
DC Voltage
NMRR :
CMRR :
Input Impedance :
AC Voltage
CMRR :
Input Impedance:
1)
Resistance
Audible Continuity Tester
Diode Tester
Open Circuit Voltage
< 1.6 VDC
Capacitance
1)
2)
3)
warning voltage of approximately 2.4V
DC Current (Clamp-on)
1) Induced error from adjacent current-carrying conductor: < 0.01A/A
2) ∆ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A.
Selection by RANGE button manually, and is specified from AC 40mV and up
Additional 50.00nF range accuracy is not specified
Accuracies with film capacitor or better
Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery
50Hz ~ 500Hz
50Hz ~ 60Hz
60Hz ~ 500Hz
50Hz ~ 500Hz
Open Circuit Voltage :
Open Circuit Voltage:
Range: 400.0Ω; Accuracy:
Audible threshold:
400.0A
1000A
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23℃ ± 5℃ & less than 75% R.H.
Range
400.0 mV
4.000V, 40.00V, 400.0V
600V
>50dB @ 50/60Hz
>120dB @ DC, 50/60Hz, Rs=1kΩ
10MΩ, 30pF nominal (1000MΩ for 400.0mV range)
400.0mV 1)
4.000V, 40.00V, 400.0V
4.000V, 40.00V, 400.0V
600V
>60dB @ DC to 60Hz, Rs=1kΩ
10MΩ, 30pF nominal
400.0Ω
4.000kΩ, 40.00kΩ, 400.0kΩ
4.000MΩ
40.00MΩ
0.4VDC typical
0.4VDC typical
1.5% + 6d
between 10Ω and 120Ω.
Test Current (Typical)
0.4mA
500.0nF, 5.000μF, 50.00μF,
500.0μF, 3000μF
0.0A ~ 400.0A
400A ~ 800A
800A ~ 900A
900A ~ 1000A
1)
Accuracy
0.3% + 3d
0.5% + 3d
1.0% + 4d
4.0% + 4d
1.0% + 4d
1.5% + 4d
2.0% + 4d
0.8% + 6d
0.6% + 4d
1.0% + 4d
2.0% + 4d
1.5% + 4d
1.5% + 4d
2.0% + 4d
5.0% + 30d
3.5% + 6d
1) 2)
1) 2)
1) 2)
www.Amprobe.com
2) 3)
1) 2)
Data Sheet