FLUKE-561 Fluke, FLUKE-561 Datasheet - Page 2

Environmental Test Equipment & Accessories HVACPRO IR THERMO- METER

FLUKE-561

Manufacturer Part Number
FLUKE-561
Description
Environmental Test Equipment & Accessories HVACPRO IR THERMO- METER
Manufacturer
Fluke
Type
Thermometersr
Datasheet

Specifications of FLUKE-561

Battery Type
2 AA
Hold Time
7 Sec
Time, Response
500 mSec
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2558118
Product specifications
Optional accessories
Temperature range
Display resolution
D:S (Distance to spot size)
Easy emissivity selector
Display accuracy [Assumes ambient operating
temperature of 23 °C (73 °F) to 25 °C (77 °F)]
Response time
Repeatability
Spectral response
Laser sighting
Laser shutoff
Laser power
Relative humidity
Power
Battery life (alkaline)
Display hold
Backlit display
Operating temperature
Storage temperature
MAX, MIN, DIF temperatures
Thermocouple type K mini-adapter input
Thermocouple type K Velcro
Warranty
Model
80PK-1 Bead Probe
80PK-3A Surface Probe
80PK-EXT Extension Wire Kits
80CK-M type K Male
Mini-Connectors
80PK-8 Pipe Clamp
Temperature Probe
80PK-22 SureGrip
Temperature Probe
80PK-24 SureGrip
Temperature Probe
80PK-25 SureGrip
Temperature Probe
80PK-26 SureGrip
Temperature Probe
80PK-27 SureGrip
Surface Temperature Probe
H6 Infrared Thermometer
Holster
Immersion
Air
Piercing
Tapered
Industrial
®
pipe probe
Features
• K-type thermocouple for general-purpose applications
• Measurement range: -40 °C to 260 °C (-40 °F to 500 ºF)
• One-year warranty
• K-type thermocouple for flat or curved surfaces such as plates and rollers
• Measurement range: 0 °C to 260 °C (32 ºF to 500ºF)
• One-year warranty
• Extending and repairing K-type thermocouple wires
• Kit includes 3 meters of thermocouple wire and 1 pair of male/female mini-connectors
• Maximum continuous exposure temperature: 260 ºC (500 ºF)
• 80PK-EXT is compatible with K-type thermometers
• One-year warranty
• Isothermal screw terminal for K wire
• Suitable for up to 20 gauge thermocouple wire
• Color-coded to industry standards (K-yellow)
• Two per package
• One-year warranty
• K-type thermocouple for fast temperature and superheat measurements of pipe surfaces
• Durable ribbon sensor
• Measurement range: -29 °C to149 °C (-20 ºF to 300 ºF) for pipe diameters from 6.4 mm to
• One-year warranty
• K-type thermocouple for use in liquids and gels
• Measurement range: -40 °C to 1090 °C (-40 ºF to 1994 ºF)
• One-year warranty
• K-type thermocouple for use in air and non-caustic gas measurements
• Bead protected by perforated baffle
• Measurement range: -40 °C to 816 ºC (-40 ºF to 1501 ºF)
• One-year warranty
• K-type thermocouple suitable for food industry, liquids, and gels
• Measurement range: -40 °C to 350 °C (-40 ºF to 662 ºF)
• One-year warranty
• K-type thermocouple with tapered tip for use in air, non-caustic gas and surface applications
• Measurement range: -40 °C to 816 ºC (-40 ºF to 1501 ºF)
• One-year warranty
• K-type thermocouple for surfaces in rugged environment
• Durable ribbon sensor
• Measurement range: -127 °C to 600 °C (-196 ºF to 1112 ºF)
• One-year warranty
• Snap-on loop attaches to belt
• Durable nylon holster
• Velcro
34.9 mm (0.25 in to 1.37 in)
®
closures provide quick access and secure storage
Fluke 561
-40 °C to 550 °C (-40 °F to 1022 ° F)
0.1 °C (0.1 °F) of reading
12:1
Adjustable with three settings: low (0.3), medium (0.7). high (0.95)
± 1.0 % of reading or ± 1 °C (± 2 °F), whichever is greater;
below 0 °C (32 °F), ± 1 °C (± 2 °F) ± 0.1°/1°
500 mSec (95 % of reading)
± 0.5 % of reading or ± 1 °C (± 2 °F), whichever is greater
8 µm to 14 µm
Single-point laser
Laser turns off above ambient temperature of 40 °C (104 °F)
Class 2 (II) operation; output <1 mW, wavelength 630 nm to 670 nm
10 % to 90 % RH non-condensing, at < 30 °C (86 °F)
2 AA batteries (alkaline or NiCD)
12 hours
7 seconds
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC),
low battery, F/C indicator, and Scan/Hold options
0 °C to 50 °C (32 °F to 120 °F)
-20 °C to 65 °C (-25 °F to 150 °F)
Yes
Yes, compatible with industry standard type K probes with
mini-connector
Yes, with a temperature range of 0 °C to 100 °C (32 °F to 212 °F)
and accuracy of ± 2.2 °C (± 4 °F)
Two-year
Ordering information
Fluke-561 Infrared and Contact
Includes: Infrared thermometer with
contact thermometer capabilities,
K-type thermocouple Velcro
probe, hard carrying case, AA batteries,
and users manual.
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006, 2007 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 8/2007 2630651 D-EN-N Rev D