VPL25-1900 Triad Magnetics, VPL25-1900 Datasheet

Transformers 50VA 25.2V@1.984A

VPL25-1900

Manufacturer Part Number
VPL25-1900
Description
Transformers 50VA 25.2V@1.984A
Manufacturer
Triad Magnetics
Datasheet

Specifications of VPL25-1900

Power Rating
50 VA
Primary Voltage Rating
230 V
Secondary Voltage Rating
25.2 V
Mounting Style
Chassis
Dimensions
101.6 mm L x 57.15 mm W x 65.07 mm H
Product
Transformers - Miscellaneous
Height
65.07 mm
Length
101.6 mm
Width
57.15 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
VPL25-1900
Electrical Specifications (@25C)
1. Maximum Power: 25.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz, Parallel: 115VAC@
3. Output Voltage
4. Voltage Regulation: 20% TYP @ full load to no load
5. Hipot: 3500VAC between primary to secondary and windings to core.
6. Recommended Fuse
Construction:
Dual winding construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements. Shrouds are provided over the
connections of the leads to the windings on both primary and secondary coils. Devices are
designed with a minimum of 6mm creepage distance between the primary and secondary
and are manufactured with a Class B (130°C) insulation system.
Agency Files:
UL File: E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3
cUL: File E65390, For Canadian Use (CSA 22.2, No.66.1-06 and No.66.3-06)
T UV Certificate No.: R72072385, EN60950, Information Technology
Dimensions:
2.562
Weight: 2.3 lbs.
Connections
Input: Series – BLK to BLU, Jumper WHT to BRN
Output: RED to YEL
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
2
3
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
Non-Inherently limited. Class 2 not wet, Class 3 wet.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
A
4.00
Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU
B
3
:
2.250
1
Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or,
: 25.2V CT@ 1.984A
C
Cooper Bussmann p/n BK/MDL-2 ½, 2.5A 250V, ¼ x 1 ¼
2
:
3.562
D
Units: In inches
8.00
E
22520B Temescal Canyon Road
Corona, California
92883
0.187
F
P
Chassis Mount : International Series
O W E R
50/60Hz
T
Publish Date: October 26, 2009
R A N S F O R M E R
F
A
BRN
WHT
BLU
BLK
SCHEMATIC
B
D
RED
YEL
C
E

Related parts for VPL25-1900

Related keywords