VPL36-1400 Triad Magnetics, VPL36-1400 Datasheet

Transformers 50VA 36V@1.389A 18V@2.778A

VPL36-1400

Manufacturer Part Number
VPL36-1400
Description
Transformers 50VA 36V@1.389A 18V@2.778A
Manufacturer
Triad Magnetics
Type
Powerr
Series
Worldr
Datasheets

Specifications of VPL36-1400

Power Rating
50 VA
Primary Voltage Rating
230 V
Secondary Voltage Rating
36 V
Mounting Style
Chassis
Dimensions
101.6 mm L x 57.15 mm W x 65.07 mm H
Product
Transformers - Miscellaneous
Height
65.07 mm
Length
101.6 mm
Width
57.15 mm
Brand/series
World Series™/VPL Series
Configuration
Bobbin
Current, Secondary
2.778/1.389 A
Frequency
50/60 Hz
Length, Lead
8 "
Mounting Hole Centers
3.562 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Power, Rating
50 VA
Standards
UL
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
18/36 VAC
Weight
2.3 lbs.
Transformer Mounting
Panel
Peak Reflow Compatible (260 C)
No
Transformer Type
Power
Supply Voltage
230V
Output Current
2.778A
Current Rating
2.778A
Leaded Process Compatible
No
Rohs Compliant
Yes
Secondary Voltages
2 X 18V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
VPL36-1400
Electrical Specifications (@25C)
1. Maximum Power: 50.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz, Parallel: 115VAC@ 50/60Hz
3. Output Voltage – Series
4. Voltage Regulation: 20% TYP @ full load to no load
5. Hipot: 3500VAC between primary to secondary and windings to core.
6. Recommended Fuse
Construction:
Dual winding construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements. Shrouds are provided over the
connections of the leads to the windings on both primary and secondary coils. Devices are
designed with a minimum of 6mm creepage distance between the primary and secondary
and are manufactured with a Class B (130°C) insulation system.
Agency Files:
UL File: E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3
cUL: File E65390, For Canadian Use (CSA 22.2, No.66.1-06 and No.66.3-06)
TUV Certificate No.: R72072385, EN60950, Information Technology
Dimensions:
2.562
Weight: 2.3 lbs.
Connections
Input: Series – BLK to BLU, Jumper WHT to BRN
Output: Series – RED to GRY, Jumper YEL to VIO
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
Non-Inherently limited. Class 3.
Non-Inherently limited. Class 2 not wet, Class 3 wet.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
A
4.00
Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU
Parallel – RED to GRY, Jumper RED to VIO and YEL to GRY
B
Series: Littelfuse p/n 313 1.5HXP, 1.5A 250V, slow blow, ¼ x 1 ¼ or,
Parallel: Littelfuse p/n 313 3HXP, 3.0A 250V, slow blow, ¼ x 1 ¼ or,
4
:
2.250
C
Cooper Bussmann p/n BK/MDL-1 ½, 1.5A 250V, ¼ x 1 ¼
Cooper Bussmann p/n BK/MDL-3, 3A 250V, ¼ x 1 ¼
3
:
3.562
1
: 36V CT@ 1.389A, Parallel
D
Units: In inches
8.00
E
22520B Temescal Canyon Road
Corona, California
92883
0.187
F
2
: 18V @ 2.778A
P
Chassis Mount : International Series
O W E R
T
Publish Date: October 26, 2009
R A N S F O R M E R
F
A
BRN
WHT
BLU
BLK
SCHEMATIC
B
D
RED
YEL
GRY
VIO
C
E

Related parts for VPL36-1400

Related keywords