78604/1C Murata Power Solutions Inc, 78604/1C Datasheet - Page 4

Transformers 2000uH 2:1 Turns

78604/1C

Manufacturer Part Number
78604/1C
Description
Transformers 2000uH 2:1 Turns
Manufacturer
Murata Power Solutions Inc
Type
Pulse Transformersr
Datasheet

Specifications of 78604/1C

Mounting Style
Through Hole
Dimensions
9.52 mm L x 9 mm W x 6.35 mm H
Product
PCB Mount Transformers
Height
6.35 mm
Length
9.52 mm
Number Of Outputs
1
Operating Temperature Range
0 C to + 70 C
Secondary Resistance
0.6 Ohms
Termination Style
DIP
Turns Ratio
2:1
Width
9 mm
Inductance
2000µH
Dc Resistance
600mohm
Et Constant
20V/µs
Isolation Voltage
1000Vrms
Transformer Mounting
PC Board
Dc Resistance Max
0.6ohm
Mounting Type
PC Board
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
TUBE OUTLINE DIMENSIONS
www.murata-ps.com
(0.023±0.005)
0.60±0.15
5.50 (0.22)
4.00 (0.16)
Unless otherwise stated all dimensions in mm (inches) ±0.25 (0.01).
15.70 (0.62)
Tube length: 465±2 (18.3±0.08). Tube quantity: 50.
10.95
(0.43)
(0.15)
3.80
Tube material: Antistatic coated clear pvc.
12.95
(0.51)
TECHNICAL NOTES
ISOLATION
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Volt-
age’, ‘Proof Voltage’, ‘Dielectric Withstand
Voltage’ & ‘Isolation Test Voltage’ are all terms
that relate to the same thing, a test voltage,
applied for a specifi ed time, across a compo-
nent designed to provide electrical isolation, to
verify the integrity of that isolation.
All products in this series are 100% production
tested at their stated isolation voltage.
A question commonly asked is, “What is the
continuous voltage that can be applied across
the part in normal operation?”
For a part holding no specifi c agency approv-
als both input and output should normally be
maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test
voltage represents a measure of immunity to
transient voltages and the part should never
be used as an element of a safety isolation
system. The part could be expected to function
correctly with several hundred volts offset
applied continuously across the isolation bar-
rier; but then the circuitry on both sides of the
barrier must be regarded as operating at an
unsafe voltage and further isolation/insulation
systems must form a barrier between these
circuits and any user-accessible circuitry ac-
cording to safety standard requirements.
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without
notice.
VOLTAGE
Technical enquiries - email: mk@murata-ps.com, tel:
General Purpose Pulse Transformers
REPEATED HIGH-VOLTAGE
ISOLATION TESTING
It is well known that repeated high-voltage
isolation testing of a barrier component can
actually degrade isolation capability, to a
lesser or greater degree depending on ma-
terials, construction and environment. This
series has toroidal isolation transformers,
with no additional insulation between pri-
mary and secondary windings of enameled
wire. While parts can be expected to with-
stand several times the stated test voltage,
the isolation capability does depend on the
wire insulation. Any material, including this
enamel (typically polyurethane) is suscep-
tible to eventual chemical degradation when
subject to very high applied voltages thus
implying that the number of tests should be
strictly limited. We therefore strongly advise
against repeated high voltage isolation test-
ing, but if it is absolutely required, that the
voltage be reduced by 20% from specifi ed
test voltage.
This consideration equally applies to agency
recognized parts rated for better than
functional isolation where the wire enamel
insulation is always supplemented by a
further insulation system of physical spacing
or barriers.
786 Series
KMP_786C_B04 Page 4 of 4
© 2009 Murata Power Solutions, Inc.
+44 (0)1908 615232

Related parts for 78604/1C