MW4024-760F-NC-WH Elpac, MW4024-760F-NC-WH Datasheet - Page 2

no-image

MW4024-760F-NC-WH

Manufacturer Part Number
MW4024-760F-NC-WH
Description
Plug-In AC Adapters 40W 24V 1.67A Med. Wht.
Manufacturer
Elpac
Type
Medicalr
Datasheet

Specifications of MW4024-760F-NC-WH

Mounting Style
Desktop
Input Voltage (nominal)
100 VAC to 240 VAC
Number Of Outputs
1
Output Power Rating
40 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
1.67 A
Dc Output Connector
2.5 mm Barrel Plug
Dc Output Cord Length
6 ft
Ac Plug Included/required
Required
Commercial/medical
Medical
Power Supply Output Type
Fixed
Power Rating
40W
Input Voltage
100V AC To 240V AC
Output Voltage
24V
Output Current
1.67A
Output Connector
Barrel Plug
Power Supply Mounting
Desktop
Output Type
Fixed
Brand/series
MW40 Series
Configuration
Enclosed
Mounting Type
Desktop
Operation
Switching
Output
24 VDC @ 1.67 A
Power, Output
40 W
Primary Type
AC-DC
Special Features
High Efficiency, Output Floating
Voltage, Input
100 to 240 VAC
Voltage, Output
24 VDC
Input
100-240 VAC, 50/60 Hz
Ripple/noise
±0.5% V p-p
Operating Temperature
0-40°C
Ul60601-1, Csa
C22.2 No. 601.1-M90, IEC60601-1
Terminal Type
Barrel
Rohs Compliant
Yes
No. Of Outputs
1
Output Power Max
40W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
MW4009-760F-NC-BK
MW4012-760F-NC-BK
MW4015-760F-NC-BK
MW4018-760F-NC-BK
MW4024-760F-NC-BK
Notes
1) Maximum peak load (48W) lasting 500ms with a maximum 10% duty cycle.
2) Includes initial setting, line regulation, load, regulation, and thermal drift.
3) Typical at 115VAC
Efficiency
MTBF
Size
Weight
Standard
Input Cable
Connection on
Power Supply Body
Model Number
General
Input Configuration
Mechanical Drawing
1.30" [33.0mm]
Avg. Efficiency 86.4% @ 115VAC;
85.7% @ 230VAC
min. 200,000 hours demonstrated
5.0 (127.0mm) x 3.0 (76.2 mm) x 1.3
(33.0mm)
0.8 lbs (.36 kg)
Not Provided
IEC 320 C14 Receptacle
Output Voltage
12.0V
15.0V
18.0V
24.0V
1-888-357-2280
9.0V
|
saleselpac@iccus.com
Operating
Temperature
Storage
Temperature
Relative
Humidity
Cooling
Vibration
Standard
Output Cable
Connector
(PSU side)
Mating
Connector
Environmental
Output Configuration
Output Current
5.07" [128.8mm]
5.00" [127.0mm]
4.4A
3.3A
2.7A
2.2A
1.7A
0 – 40C, linearly derated to 50%
load at 60C
-40°C to +85°C
5-95%, non-condensing
Natural Convection
All units production tested to
19.6m/s
6ft
Switchcraft 760 or equivalent
Switchcraft 712A or equivalent
|
www.iccus.com
2
Peak Current
|
1562 Reynolds Avenue Irvine, CA 92614
5.3A
4.0A
3.2A
2.6A
2.0A
Medical Switch Mode Power Supply
1
MW40 Series
Total Regulation
Emissions
Immunity
Certified by
TUV to the
following:
Center
Outside
EMC & Safety
Output Pin Assignments
Ordering Options Available
(Contact Factory)
White Case
Grounded Output
±5%
±5%
±5%
±5%
±5%
FCC class B, CISPR11 class B
EN61000-3-2, -3
EN60601-4-2, -3, -4, -5, -6, -8, -11
cTUVus
UL 60601-1
CAN/CSA-22.2 No.601.1-M90
CB per IEC60601-1
CE marked to LVD
+V1
Return
2
Minimum Efficiency
Rtn
40 watts
84%
86%
87%
87%
88%
+V
3