TR70A12-02A03 Cincon, TR70A12-02A03 Datasheet - Page 2

Plug-In AC Adapters 70W 90-264VAC 12VDC 5.5A 2.5mm DC R/A

TR70A12-02A03

Manufacturer Part Number
TR70A12-02A03
Description
Plug-In AC Adapters 70W 90-264VAC 12VDC 5.5A 2.5mm DC R/A
Manufacturer
Cincon
Datasheet

Specifications of TR70A12-02A03

Mounting Style
Desktop
Input Voltage (nominal)
90 VAC to 264 VAC
Number Of Outputs
1
Output Power Rating
70 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
5.5 A
Dc Output Connector
2.5 mm Barrel Plug
Dc Output Cord Length
1800 mm
Ac Plug Included/required
Required
Commercial/medical
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
INPUT SPECIFICATIONS:
Voltage …....………........…....................................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Inrush Current ………………….………….................... 60A max. @240Vac
Conducted EMI ………………………………………… CISPR/FCC Class B
Leakage Current …………………………………………….…… 3.5mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection ……………………..……….…………… Continuous
Over Voltage Protection ………………..........................................… Option
Temperature Coefficient …………………….............................… ±0.05%/ ℃
GENERAL SPECIFICATIONS:
Isolation ………………………………………… Input to output = 4,242VDC
Operating Temperature .............................. 0 ~ 60 ℃ (see derating curve)
Storage Temperature ……………………………...….......……........ -20~85 ℃
Humidity …………………...….......……....... 93% RH max. Non condensing
Cooling ………………………………….………………… Natural Convection
Switching Frequency …………………………………………60KHz Typical
MTBF ……… MIL-HDBK-217F, GB, at 25 ℃ /115VAC ………. 200K hrs min.
Altitude …………………………………………………………………… 2000m
Dimensions ……..…. 5.197x2.283x1.181 inches (132.00x58.00x30.00 mm)
Weight ……………………………………………………… 345g(0.76 Pounds)
AC Inlet ……………….…………………………………...……… IEC320/C14
SAFETY AND EMC:
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B
Safety ………………………………… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
All Dimensions are in inches(mm)
Tolerance:Inches:X.XXX±0.02
IEC320/C14
Millimeters:X.XX±0.5
Specifications
EN61000-6-3,EN61000-3-2,EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
2
DC Plug type: V+ ─●)─ V-
DC Plug :Right Angle(ψ5.5/ψ2.1) L12mm
18AWG/1800mm
NOTE:
1. Voltage setpoint at 60% full load
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60% to
5. ”Various TR Series adapters are PSE certified. PSE certification
Ripple & Noise measurement @20MHz BW.
20% load (60% +/- 40% full load)
alone is not sufficient for importation into Japan. A valid PSE mark
must contain the name of the importer as shown in the example below.
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
PSE mark if importer name is not supplied. Consult factory or local
representative for details”
100%
LED
75%
50%
25%
0%
TR70 Series Derating Curve
0
10
20LFM(Natural Convection)
Ambient Temperature(
20
30
40
o
C)