TR25120-A-12A03 Cincon, TR25120-A-12A03 Datasheet - Page 2

Plug-In AC Adapters 25W 90-264VAC 12VDC 2.1A 2.5mm DC

TR25120-A-12A03

Manufacturer Part Number
TR25120-A-12A03
Description
Plug-In AC Adapters 25W 90-264VAC 12VDC 2.1A 2.5mm DC
Manufacturer
Cincon
Datasheet

Specifications of TR25120-A-12A03

Mounting Style
Wall
Input Voltage (nominal)
100 VAC to 240 VAC
Number Of Outputs
1
Output Power Rating
25 W
Output Voltage (channel 1)
12 V
Output Current (channel 1)
2.1 A
Dc Output Connector
2.5 mm Barrel Plug
Dc Output Cord Length
1800 mm
Ac Plug Included/required
Included
Commercial/medical
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….……………................... 0.7A max.
Inrush Current ………………….……………................... 50A max. @240Vac
Conducted EMI …………………………….…………... CISPR/FCC Class B
Leakage Current …………………………………………………. 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Voltage Protection …………..……. ............. TVS Component to Clamp
Temperature Coefficient ……………………............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
Isolation ……………………………………..…… Input to output = 4,242VDC
Operating Temperature ................................... 0 ~ 60 ℃ (see derating curve)
Storage Temperature ……………………………...….......……........ -20~85 ℃
Humidity …………………...….......….......... 93% RH max. Non condensing
Cooling …………………………………………………….. Natural Convection
Switching Frequency ………………………………………….. 31KHz Typical
MTBF …………..… MIL-HDBK-217F, GB, 25 ℃ /115VAC …. 200K hrs min.
Altitude …………………………………………………………………… 2000m
Dimensions ……….….. 3.169x1.932x2.205Inches (80.5x49.06x56.00mm)
Weight ………………………………………………….…… 280g(0.62 Pounds)
SAFETY AND EMC:
Emission and lmmunity ……..….… EN55022 Class B, FCC Part 15 Class B
Safety …………………………….…… IEC60950-1, EN60950-1, UL60950-1
NOTE:
1. Voltage setpoint at 60% full load
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60% to
TR25R Series Derating Curve
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
Ripple & Noise measuring @20MHz BW.
20% load (60% +/- 40% full load)
100%
75%
50%
25%
0%
0
10
20LFM(Natural Convection)
Specifications
Ambient Temperature(
20
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
30
40
o
C)
50
60
2
Mechanical Specification