CLG-100-36 Mean Well, CLG-100-36 Datasheet

Linear & Switching Power Supplies 36V 2.65A 95.4W Active PFC Function

CLG-100-36

Manufacturer Part Number
CLG-100-36
Description
Linear & Switching Power Supplies 36V 2.65A 95.4W Active PFC Function
Manufacturer
Mean Well
Datasheet

Specifications of CLG-100-36

Product
Switching
Commercial/medical
Commercial
Output Power Rating
95 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
36 V
Output Current (channel 1)
2.65 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLG-100-36
Manufacturer:
MITSUBISHI
Quantity:
3 315
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
INRUSH CURRENT(max.)
LEAKAGE CURRENT
OVER CURRENT (Typ.)
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
EMI CONDUCTION & RADIATION
100W Single Output Switching Power Supply
Note.4
Note.3
Note.5
Note.5
Note.8
Note.2
Note.7
90
Protection type : Shut down o/p voltage, re-power on to recover
CLG-100-12
12V
9 ~ 12V
5A
60W
150mVp-p
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
1200ms, 80ms / 230VAC
60ms / 230VAC
90 ~ 295VAC
47 ~ 63Hz
PF>0.95/230VAC
1.0Kg; 12pcs/13Kg/0.49CUFT
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down and latch off o/p voltage, re-power on to recover
-30 ~ +70
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
301Khrs min.
222.2*68*38.8mm (L*W*H)
84.5%
12V:0.8A/115VAC
COLD START 40A/230VAC
<0.75mA / 240VAC
13 ~ 16V
3.0%
1.0%
2.0%
0.03%/
10
(0 ~ 50 )
(RTH2)
(Refer to output load derating curve)
EN61000-3-2 Class C
MIL-HDBK-217F (25 )
CLG-100-15
15V
11.25 ~ 15V
5A
75W
150mVp-p
127 ~ 417VDC
86.5%
16.5 ~ 20V
3.0%
30
0.4A/230VAC
I/P-FG:1.88KVAC
PF>0.95/115VAC at full load
ms / 115VAC
1200ms, 80ms / 115VAC
at full load
CLG-100-20
20V
15 ~ 20V
4.8A
96W
150mVp-p
( 75% load) ; EN61000-3-3
LPS
90%
22 ~ 27V
3.0%
15V:0.9A/115VAC
O/P-FG:0.5KVAC
at full load
CLG-100-24
24V
18 ~ 24V
4A
96W
150mVp-p
90%
27 ~ 34V
PF 0.9 at 75 ~ 100% load
3.0%
0.45A/230VAC
CLG-100-27
27V
20.25 ~ 27V
3.55A
95.85W
150mVp-p
90%
30 ~ 36V
3.0%
C L G - 1 0 0
20V ~ 48V:1.1A/115VAC
IP67
CLG-100-36
36V
27 ~ 36V
2.65A
95.4W
150mVp-p
90%
39 ~ 48V
2.0%
File Name:CLG-100-SPEC 2011-01-17
0.55A/230VAC
CLG-100-48
48V
36 ~ 48V
2A
96W
200mVp-p
89%
52 ~ 64V
2.0%
s e r i e s

Related parts for CLG-100-36

CLG-100-36 Summary of contents

Page 1

... I/P-FG:1.88KVAC O/P-FG:0.5KVAC EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 MIL-HDBK-217F ( IP67 CLG-100-27 CLG-100-36 CLG-100-48 27V 36V 48V 20.25 ~ 27V 27 ~ 36V 36 ~ 48V 3.55A 2.65A 2A 95.85W 95.4W 96W 150mVp-p 150mVp-p 200mVp-p 3.0% 2.0% 2 ...

Page 2

... Static Characteristics 100 (HORIZONTAL Case No. 954A 300 20 18AWG 2C 4.2 4PL RECTIFIERS & FILTER O.L.P. DETECTION CIRCUIT O.V.P. 100 125 135 145 155 165 175 180 200 INPUT VOLTAGE (V) 60Hz File Name:CLG-100-SPEC 2011-01- Unit:mm +V(Red) -V(Black) Fosc : 100KHz +V -V fosc : 100KHz 230 295 ...

Page 3

... Single Output Switching Power Supply Power Factor Characteristic Power factor will be higher than 0.9 when output loading is 75% or higher. Constant Current Mode EFFICIENCY vs LOAD (48V Model) CLG-100 series possess superior working efficiency that up to 89% can be reached in field applications 10% 20% 30% 40% ...

Related keywords