DR-100-12 Mean Well, DR-100-12 Datasheet

Linear & Switching Power Supplies 90W 12V 7.5A

DR-100-12

Manufacturer Part Number
DR-100-12
Description
Linear & Switching Power Supplies 90W 12V 7.5A
Manufacturer
Mean Well
Datasheet

Specifications of DR-100-12

Product
Switching
Commercial/medical
Commercial
Output Power Rating
90 W
Input Voltage
88 VAC to 264 VAC, 124 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
7.5 A
Mounting Style
DIN Rail
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
OVER TEMPERATURE
EMI CONDUCTION & RADIATION
INRUSH CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
100W Single Output Industrial DIN Rail Power Supply
Note.3
Note.6
Note.2
90
Protection type : Shut down o/p voltage, re-power on to recover
12V
7.5A
0 ~ 7.5A
90W
120mVp-p
12 ~ 15V
2700ms, 80ms/230VAC
50ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
DR-100-12
3A/115VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
16 ~ 20V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL60950-1, TUV EN60950-1 a
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN61204-3, EN55022 ClassB
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
486K hrs min.
100*93*56mm (W*H*D)
0.35Kg; 36pcs/13.6Kg/0.89CUFT
87%
COLD START 30A/115VAC
2.0%
1.0%
1.0%
0.03%/
15 (RTH2) detect on heatsink of power transistor
(0 ~ 50 )
(Refer to output load derating curve)
1.6A/230VAC
MIL-HDBK-217F (25 )
124 ~ 370VDC
18ms/115VAC at full load
2700ms, 80ms/115VAC at full load
pproved, design refer to
45A/230VAC
15V
6.5A
0 ~ 6.5A
97.5W
120mVp-p
15 ~ 18V
DR-100-15
19 ~ 23V
87%
1.0%
1.0%
1.0%
EN50178
D R - 1 0 0
24V
4.2A
0 ~ 4.2A
100.8W
150mVp-p
24 ~ 29V
DR-100-24
30 ~ 35V
89%
1.0%
1.0%
1.0%
File Name:DR-100-SPEC 2010-05-10
..
s e r i e s

Related parts for DR-100-12

DR-100-12 Summary of contents

Page 1

... Single Output Industrial DIN Rail Power Supply SPECIFICATION MODEL DR-100-12 DC VOLTAGE 12V RATED CURRENT 7.5A CURRENT RANGE 0 ~ 7.5A RATED POWER 90W RIPPLE & NOISE (max.) 120mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE 12 ~ 15V VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME 2700ms, 80ms/230VAC HOLD UP TIME (Typ ...

Page 2

... FILTER PWM O.L.P. CONTROL Output Derating VS Input Voltage 100 230V AC Input (VERTICAL Case No.970A 68 45 46.5 46 RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. 95 100 110 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz File Name:DR-100-SPEC 2010-05- Unit: Ta=25 240 264 ...

Related keywords