RSP-2400-12 Mean Well, RSP-2400-12 Datasheet - Page 5

Linear & Switching Power Supplies 2000.4W 12V 166.7A ACTIVE PFC FUNCTION

RSP-2400-12

Manufacturer Part Number
RSP-2400-12
Description
Linear & Switching Power Supplies 2000.4W 12V 166.7A ACTIVE PFC FUNCTION
Manufacturer
Mean Well
Datasheet

Specifications of RSP-2400-12

Product
Switching
Output Power Rating
2000 W
Input Voltage
180 VAC to 264 VAC, 254 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
166.7 A
Mounting Style
Chassis
Open Frame/enclosed
Enclosed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4.Current Sharing
5.Select O.L.P mode
(1)Parallel operation is available by connecting the units shown as below
(2)The voltage difference among each output should be minimized that less than 2% is required.
(3)The total output current must not exceed the value determined by the following equation.
(4) In parallel operation 3 units is the maximum, please consult the manufacturer for other applications.
(5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit.
(6) Wires of remote sensing should be kept at least 10 cm from input wires.
(7) Under parallel operation, the "output voltage trim" function is not available.
(8) When in parallel operation, the minimum output load should be greater than 2% of total output load (Min. Load >2% rated current per unit number of unit)
(1)Remove the shorting connector on CN3 that is shown in Fig 5.1, the O.L.P. mode will be "continuous constant current limiting".
(2)Insert the shorting connector on CN3 that is shown in Fig 5.2, the O.L.P. mode will be "constant current limiting with delay shutdown after 5 seconds,
(+S,-S and CS are connected mutually in parallel):
re-power on to recover".
(Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9
No.1(Master)
No.2(Slave)
No.3(Slave)
AC/L
AC/L
AC/L
OLP Mode : constant current limiting
AC/N
AC/N
AC/N
2400W Single Output Power Supply
Fig. 5.1 Remove the CN3
OL-SD
OLP
CN1
CN1
CN1
CN2
CN2
CN2
CS
CS
CS
CS
CS
CS
+S
-S
+S
-S
+S
-S
+S
-S
+S
-S
+S
-S
-V
-V
-V
+V
+V
+V
Fig. 5.2 Insert the CN3
OLP Mode : constant current limiting with delay shutdown after 5 seconds
OL-SD
OLP
+S
-S
+V
-V
Load
R S P - 2 4 0 0
File Name:RSP-2400-SPEC 2010-10-18