TYP60-344 Tamura, TYP60-344 Datasheet

Linear & Switching Power Supplies 50W 5V 6A 12V 2A -12V 0.5A

TYP60-344

Manufacturer Part Number
TYP60-344
Description
Linear & Switching Power Supplies 50W 5V 6A 12V 2A -12V 0.5A
Manufacturer
Tamura
Datasheet

Specifications of TYP60-344

Product
Switching
Commercial/medical
Commercial
Output Power Rating
50 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
6 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.5 A
Mounting Style
Chassis
Dimensions
127 mm L x 76.2 mm W x 32 mm H
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TYP60
50 Watts Output Power
70% TYP Efficiency
Electrical Specifications
Available Voltage Outputs
Input Voltage:
Input Current:
Inrush Current:
EMC:
Input Protection:
Output Power:
Minimum Load:
Line Regulation:
Load Regulation:
Cross Regulation:
PARD (Ripple and Noise):
Remote Sense:
Hold-up Time:
Turn on Delay:
Model
TYP60-344
Voltage
Codes
90-264 VAC, 47-63 Hz, single phase
20 A peak
47CFR FCC part 15; and CISPR22/EN55022
Internal AC line fuse; 250 VAC, 3.15A
50W with 10 CFM air
> 0.4A for V1 and V2
V1, V3 =± 0.2%
V2 = ± 2.0%
± 2% for V1 and V2
± 8% for V2
± 5% for V3
V1 output: 1% or 50mV, whichever is higher
V2 and V3 outputs: 1% or 100mV, which ever
Standard on V1 up to 400mV of cable drop
>10 ms @ full load after removal of AC input.
2 seconds
At 115VAC, 50W load, maximum input current
shall be < 1.0A RMS.
Class B
± 5% for V3
(20MHz bandwidth).
is higher (20MHz bandwidth)
All outputs are protected against loss of
sense leads with internal sense connections.
Voltages
(Volts)
+5
V1
Currents
Miniature Switch Mode Power Supply
(Amps)
V1
6
Voltages
(Volts)
+12
Output Polarity:
Overvoltage Protect:
Overshoot / Undershoot:
Short Circuit Protection:
Reverse Voltage:
Case Power Protection:
Efficiency:
MTBF:
V2
H.A.L.T.
Currents
(Amps)
V2
2
tested
See Voltage Chart
V1 and V2 factory set @ 20% ±10% of
<5% overshoot with remote sense at output
Hiccup mode on short circuit of either V1 or
Normal operation after short circuit is
Overload protection on V3 is accomplished by
Automatic recovery occurs when the overload
Reverse current up to rated outputs
Standard operation interrupt (hiccup mode)
70% TYP
MIL-STD-HDBK 217E
nominal Vout
terminals.
V2 outputs.
removed.
foldback.
is removed.
>180,000 hours @ 25°C
Highly Accelerated Life Testing
Voltages
(Volts)
-12
V3
Highly
Accelerated
Life
Testing
Currents
(Amps)
0.5
V3

Related parts for TYP60-344

TYP60-344 Summary of contents

Page 1

... Hold-up Time: > full load after removal of AC input. Turn on Delay: 2 seconds Available Voltage Outputs Voltage Codes Voltages (Volts) TYP60-344 Miniature Switch Mode Power Supply H.A.L.T. Output Polarity: Overvoltage Protect: Overshoot / Undershoot: Short Circuit Protection: Reverse Voltage: Case Power Protection: Efficiency: ...

Page 2

... Model TYP60 Compliance EMC: 47CFR, FCC part 15; and CISPR 22 / EN55022 Class B Certifications UL Recognized UL60950-1 CSA C22.2 No. 60950-1-03 Dimensions are in mm [inches], unless otherwise noted SPACING FROM PRIMARY CIRCUIT TO GROUNDED COMPONENTS, AND FROM PRIMARY CIRCUIT TO SECONDARY COM- PONENTS SHOULD EXCEED 7.6 [0.3"] AFTER INSTALLATION TO MAINTAIN SAFETY ...