UCE-12/4.2-D48N-C Murata Power Solutions Inc, UCE-12/4.2-D48N-C Datasheet

DC/DC Converters & Regulators 48Vin 12Vout 4.2A 50.4W Neg polarity

UCE-12/4.2-D48N-C

Manufacturer Part Number
UCE-12/4.2-D48N-C
Description
DC/DC Converters & Regulators 48Vin 12Vout 4.2A 50.4W Neg polarity
Manufacturer
Murata Power Solutions Inc

Specifications of UCE-12/4.2-D48N-C

Output Power
50 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
4.2 A
Isolation Voltage
2.25 KV
Package / Case Size
Eighth Brick
Output Voltage
12 V
Product
Isolated
Dc / Dc Converter O/p Type
Eighth-Brick
No. Of Outputs
1
Input Voltage
36V To 75V
Power Rating
50.4W
Output Current
4.2A
Approval Bodies
CAN / CSA / EN / IEC / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FEATURES
n
n
n
n
n
n
n
n
n
n
n
n
n
RoHS compliant
Industry standard eighth-brick pinout
and package
Outputs from 1.5V to 12V up to 100W
Low profile 0.4" height with 0.9" x 2.3"
outline dimensions
36 to 75 Vdc nominal input
Fully isolated, 2250 Vdc (BASIC)
insulation
Outstanding thermal performance
and derating
Extensive self-protection and short
circuit features with no output reverse
conduction
On/Off control, trim and sense functions
Interleaved synchronous rectification
yields high efficiency over 90%
Fully protected against temperature and
voltage limits
UL/EN/IEC 60950-1 safety approvals
Qual/HALT/EMI testing is scheduled
www.murata-ps.com/rohs
For full details go to
Typical unit
 
CONTROL
REMOTE
ON/OFF
(2)
+V
–V
(3)
(1)
IN
IN
SIMPLIFIED BLOCK DIAGRAM
For efficient, fully isolated DC power in the smallest space, the UCE
open frame DC/DC converter series fit in industry-standard “eighth
brick” outline dimensions and mounting pins (on quarter-brick pinout).
Units are offered with fixed output voltages from
1.5 to 12 Volts and currents up to 40 Amps. UCEs
operate over a wide temperature range (up to +85
degrees Celsius at moderate airflow) with full rated
power. Interleaved synchronous rectifier topology
yields excellent efficiency over 90% and no reverse
output conduction.
environmental specs while delivering excellent
electrical performance in a through-hole package.
Overall noise is typically 50 mV pk-pk (low voltage
models) with fast step response. These converters
offer tight output regulation and high stability even
with no load. The unit is fully protected against
input undervoltage, output overcurrent and short
circuit. An on-board temperature sensor shuts
PRODUCT OVERVIEW
UCE’s achieve these impressive mechanical and
www.murata-ps.com
CONTROLLER
PWM
ISOLATION
TRANSFORMER
OPTO
PULSE
CONTROL
SWITCH
Technical enquiries email: sales@murata-ps.com, tel:
Typical topology is shown.
REFERENCE &
ERROR AMP
down the converter if thermal limits are reached.
“Hiccup” output protection automatically restarts
the converter when the fault is removed.
phased startup and shutdown in multi-voltage ap-
plications. To compensate for longer wiring and to
retain output voltage accuracy at the load, UCEs em-
ploy a Sense input to dynamically correct for ohmic
losses. A trim input may be connected to a user’s
adjustment potentiometer or trim resistors for output
voltage calibration. The UCE will tolerate substantial
capacitive loading for bypass-cap applications.
tions and BASIC I/O insulation provides input/output
isolation to 2250V. Radiation emission testing is
performed to widely-accepted EMC standards.
Isolated, High-Density, Eighth-Brick
INPUT UNDERVOLTAGE, INPUT
OVERVOLTAGE, AND OUTPUT
OVERVOLTAGE COMPARATORS
A convenient remote On/Off control input enables
UCEs include industry-standard safety certifica-
100W DC/DC Converters
UCE Series
MDC_UCE.A09 Page 1 of 10
+1 508 339 3000
V
+SENSE
−SENSE
+V
−V
OUT
(8)
(4)
(7)
(5)
(6)
OUT
OUT
TRIM

Related parts for UCE-12/4.2-D48N-C

UCE-12/4.2-D48N-C Summary of contents

Page 1

... For full details go to www.murata-ps.com/rohs For efficient, fully isolated DC power in the smallest space, the UCE open frame DC/DC converter series fit in industry-standard “eighth brick” outline dimensions and mounting pins (on quarter-brick pinout). PRODUCT OVERVIEW Units are offered with fixed output voltages from 1 ...

Page 2

... UCE-3.3/15-D48N-C 3.3 15 49.5 UCE-3.3/30-D48N-C 3 UCE-5/10-D48N UCE-5/20-D48N 100 UCE-12/4.2-D48N-C 12 4.2 50.4 UCE-12/8.3-D48N-C 12 8.3 99.6  Please refer to the model number structure for additional ordering part numbers and options . PART NUMBER STRUCTURE - U CE Output Configuration Unipolar/Single Eighth-Brick Package Nominal Output Voltage Maximum Rated Output ...

Page 3

... V. max hiccup output 5 4.25 autorestart. shorted to Remove ground. No overload for damage. 14.5 recovery. Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A09 Page Positive Negative Logic Logic “P” Model “N” Model Suffix Suffix OFF=open or pin to +2.5V to +1V max. +15V max. ON=Ground pin to +0 ...

Page 4

... Note: Not all model combinations are available. (7) The outputs are not intended to sink appreciable reverse current. This may damage the outputs. (8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction. = nominal nominal, full (9) All models are fully operational and meet published specifications, including “cold ...

Page 5

... Nickel underplate with gold overplate 0.67 ounces (19 grams) 0.71 ounces (20 grams) 1 ounce (28 grams) 0.81 ounces (23 grams) FCC part 15, class B, EN55022 UL/cUL 60950-1, CSA-C22.2 No. 60950-1, IEC/EN 60950-1 www.murata-ps.com UCE Series Isolated, High-Density, Eighth-Brick 100W DC/DC Converters Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A09 Page ...

Page 6

... Angles ± 2˚ Components are shown for reference only. INPUT/OUTPUT CONNECTIONS Pin Function P32 1 −Input 2 On/Off Control 3 +Input 4 −Output 5 −Sense 6 Output Trim 7 +Sense 8 +Output Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCE.A09 Page ...

Page 7

... LOAD R TRIM UP www.murata-ps.com UCE Series Isolated, High-Density, Eighth-Brick 100W DC/DC Converters − 10.22 +OUTPUT –INPUT +SENSE R TRIM DOWN ON/OFF TRIM CONTROL –SENSE +INPUT –OUTPUT Figure C. Trim Connections To Decrease Output Voltages Technical enquiries email: sales@murata-ps.com, tel: MDC_UCE.A09 Page LOAD +1 508 339 3000 ...

Page 8

... UCE-1.5/20-D48 Efficiency vs Line Voltage & Load Current @ 25º Vin = 75V 80 Vin = 48V Vin = 36V Load Current (A) UCE-1.8/30-D48 Efficiency vs Line Voltage & Load Current @ 25º Vin = 75V 80 Vin = 48V 75 Vin = 36V Load Current (A) UCE-2.5/20-D48 Efficiency vs Line Voltage & Load Current @ 25º Vin = 75V ...

Page 9

... UCE-3.3/15-D48 Efficiency Vs. Line Voltage & Load Current @ +25º Vin = 75V 85 Vin = 48V Vin = 36V Load Current (A) UCE-3.3/30-D48 Efficiency vs Line Voltage & Load Current @ 25º Vin = 75V 80 Vin = 48V 75 Vin = 36V Load Current (A) UCE-12/4.2-D48 Efficiency Vs. Line Voltage & Load Current @ +25º Vin = 75V ...

Page 10

... UCE-12/8.3-D48 Efficiency vs Line Voltage & Load Current @ 25º Vin = 75V 85 Vin = 48V Vin = 36V Load Current (A) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights ...