OKL-T/3-W5P-C Murata Power Solutions Inc, OKL-T/3-W5P-C Datasheet

DC/DC Converters & Regulators 5Vin 0.6-3.63Vout 3A 9.9W Pos Polarity

OKL-T/3-W5P-C

Manufacturer Part Number
OKL-T/3-W5P-C
Description
DC/DC Converters & Regulators 5Vin 0.6-3.63Vout 3A 9.9W Pos Polarity
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of OKL-T/3-W5P-C

Output Power
9.9 W
Input Voltage Range
2.4 V to 5.5 V
Input Voltage (nominal)
5 V
Number Of Outputs
1
Package / Case Size
12.2 mm x 12.2 mm x6.2 mm
Output Voltage
0.6 V to 3.63 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FEATURES
www.murata-ps.com
iLGA inspectable Land Grid Array
2.4-5.5Vdc input voltage range
Programmable output voltage from 0.6-3.63Vdc
Drives 200 μF ceramic capacitive loads
High power conversion effi ciency at 95.3%
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control
Certifi ed to UL/EN/IEC 60950-1 safety, 2nd Edition
RoHS-6 hazardous substance compliance
Sequence/Tracking operation (optional)
www.murata-ps.com/rohs
Sequence/Tracking
External
DC
Power
Source
(OKL2 Models)
For full details go to
 
F1
Open = On
Closed = Off
Common
+Vin
(Positive
Control
Typical unit
Typical
On/Off
On/Off)
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifi cations.
Controller
PRODUCT OVERVIEW
isolated Point-of-Load (PoL) DC/DC power convert-
ers for embedded applications. The tiny form factor
is confi gured on a Land Grid Array (LGA) assembly
measuring only 0.48 x 0.48 x 0.244 inches max.
(12.2 x 12.2 x 6.2 mm max.).
The maximum output current is 3 Amps. Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
The OKL-T/3-W5 series are miniature non-
The wide input range is 2.4 to 5.5 Volts DC.
www.murata-ps.com
Connection Diagram
Figure 1. OKL-T/3-W5
Contents
Description, Connection Diagram, Photograph
Ordering Guide, Model Numbering, Product Label
Detailed Electrical Specifi cations
Mechanical Specifi cations, Input/Output Pinout
Performance Data and Oscillograms
Technical Notes
Reference and
Error Amplifier
Programmable Output 3-Amp iLGA SMT PoLs
09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page 1 of 18
effi cient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
power sequencing of PoL’s. These units are certi-
fi ed to all standard UL/EN/IEC 60950-1 safety
certifi cations (2nd Edition) and RoHS-6 hazardous
substance compliance.
An optional sequence/tracking feature allows
OKL-T/3-W5 Series
Common
+Vout
Sense
Trim
email: sales@murata-ps.com
Page
14
1
2
3
5
7

Related parts for OKL-T/3-W5P-C

OKL-T/3-W5P-C Summary of contents

Page 1

... An optional sequence/tracking feature allows power sequencing of PoL’s. These units are certi- fi all standard UL/EN/IEC 60950-1 safety certifi cations (2nd Edition) and RoHS-6 hazardous substance compliance. Page +Vout Sense Trim Common email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 2

... C RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder) On/Off Polarity P = Positive Polarity N = Negative Polarity Model Number Product Code OKL-T/3-W5P-C L01003 OKL-T/3-W5N-C L00003 L21003 L20003 email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page Package - Pinout P83 Case C83 inches (mm) ...

Page 3

... Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. www.murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page OKL-T/3-W5 Series 6 mSec for Vout=nominal (Remote On/Off) 600 KHz Environmental OKL Models ...

Page 4

... This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation. www.murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page OKL-T/3-W5 Series email: sales@murata-ps.com ...

Page 5

... Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page Function On/Off Control Ground V OUT Sense Trim Ground ...

Page 6

... Pocket tape length before modules C Cover tape length before pocket tape www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 7.40±0.1 0.40±0.05 Start of pocket tape C B Start of cover tape Length (mm) email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page 800 ±40 200 min. 240 ±40 ...

Page 7

... On/Off Enable Delay (Vin=5V, Vout=3.3V, Iout=3A, Cload=0) Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series 65 LFM Ambient Temperature (ºC) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 8

... Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=2.5V, Iout=3A, Cload=0) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 9

... Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=1.8V, Iout=6A, Cload=0) Trace 4=Enable, Trace2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 10

... Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=1.5V, Iout=3A, Cload=0) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 11

... Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=1.2V, Iout=3A, Cload=0) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 12

... Step Load Transient Response (Vin=5V, Vout=1.0V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=1.0V, Iout=3A, Cload=0) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 13

... Step Load Transient Response (Vin=5V, Vout=0.6V, Cload=0, Iout=3A to 1.5A) www.murata-ps.com OKL-T/3-W5 Series Programmable Output 3-Amp iLGA SMT PoLs 65 LFM Ambient Temperature (ºC) On/Off Enable Delay (Vin=5V, Vout=0.6V, Iout=3A, Cload=0) Trace 4=Enable, Trace 2=Vout Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2.5A/div. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...

Page 14

... The Cbus and Lbus components simulate a typical DC voltage bus. Please note that the values of Cin, Lbus and Cbus will vary according to the specifi c converter model. www.murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page OKL-T/3-W5 Series email: sales@murata-ps.com ...

Page 15

... CAUTION: These graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude. Output Voltage Sequencing The OKL modules include a sequencing feature that enables users to implement various types of output voltage sequencing in their applications. This is accomplished via an additional sequencing pin. When not using the sequencing feature, either tie the sequence pin to Vin or leave it uncon- nected ...

Page 16

... Remote On/Off Control The OKL Series power modules can be specifi ed with either a positive or nega- tive logic polarity. See Figures 7 and 8 for On/Off circuit control. In the positive logic on/off option the unit turns on during a logic high on the On/Off pin and turns off during a logic low ...

Page 17

... C/sec Preheating Zone 240 sec max 120 150 180 Time (sec) email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page Reflow Zone 45-75 sec High trace = normal upper limit Low trace = normal lower limit 210 240 270 300 ...

Page 18

... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations OKL-T/3-W5 Series © 2011 Murata Power Solutions, Inc. email: sales@murata-ps.com 09 May 2011 MDC_OKL-T/3-W5 Series.A08 Page ...