1AV12F Honeywell, 1AV12F Datasheet

no-image

1AV12F

Manufacturer Part Number
1AV12F
Description
Proximity Sensors NPN Leadwire 12 VDC 25 degrees C
Manufacturer
Honeywell
Type
Vane Sensorr
Datasheet

Specifications of 1AV12F

Maximum Operating Temperature
+ 125 C
Supply Voltage
24 V
Supply Current
16 mA to 18.5 mA
Operating Supply Voltage
12 VDC
Minimum Operating Temperature
- 40 C
Maximum Output Current
40 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation Instructions for the
1AV Series 2 Vane Sensor
PERSONAL INJURY
Failure to comply with these instructions could
result in death or serious injury.
GENERAL INFORMATION
Hall-effect sensor and a magnet in a common
package. They are operated by passing a ferrous
vane through the gap between magnet and sensor.
AISI, 1018 or lower in carbon content. Minimum
recommended vane dimensions of 0.30 inch (7,6
mm) tooth width and .40 inch (10,1 mm) window
width are required to assure appropriate operating
characteristics.
ACTUATION
1. With no vane in gap - output is conducting
2. Vane movement Left to Right - when leading
3. After leading edge reaches “b”, assuming vane
4. For vane movement from Right to Left, output is
MECHANICAL CHARACTERISTICS
Sensing and Control
Operating
Range
12 VDC, 25 C
DO NOT USE these products as safety or
emergency stop devices, or in any other
application where failure of the product could
result in personal injury.
1AV Series Hall-effect vane sensors include a
The vane is a low carbon cold rolled steel, type
(Sinking is Low).
edge reaches “b”, the output voltage stops
conducting (Sinking goes High).
moves on through the gap; as trailing edge
reaches “d”, the output voltage will be conducting.
nonconducting when leading edge reaches “c”,
and conducting when trailing edge reaches “a”.
WARNING
Operate (a)
.39
.03
Release (b)
.41
Left
.03
.02
Diff. (b-a)
.014
WIRING DIAGRAMS
ELECTRICAL CHARACTERISTICS
Supply voltage
Supply current
Output voltage
Load current
Temperature range
Operate (d)
.51
.03
Release (c)
.49
Right
4.5 to 24 Vdc (11 + 5 typ.)
16.0 mA max. @ 25 °C
18.5 mA max. @ -40 °C
Current sinking: 0.4 V max. @
20mA
40 mA max.
-40 to +125 °C (-40 to +257 °F)
.03
PK 87573
.02
Diff. (d-c)
.014
ISSUE 3
Differential
(c-a), (d-b)
.10
L-R, R-L
.04

Related parts for 1AV12F

1AV12F Summary of contents

Page 1

Installation Instructions for the 1AV Series 2 Vane Sensor WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices any other application where failure of the product could result in personal injury. Failure to ...

Page 2

... Series 2 Vane Sensor MOUNTING DIMENSIONS (for reference only) mm in. VANE DIMENSIONS CATALOG LISTINGS Listing Type 1AV11F Open Collector 1AV12F NPN 1AV13F Current Sinking 2 Honeywell Sensing and Control TERMINALS Output 3 Common Termination Style Terminal Leadwire Leadwire Issue 3 PK 87573 LEADWIRES Red ...

Page 3

... Make certain all wiring is correct (load must be connected). 2. Measure supply voltage across positive and ground (leads/terminals) to verify that proper supply voltage is present. 3. Connect positive lead of voltmeter to output (lead/terminal). Readings should be: No vane in gap 0.4 V max. Vane in gap Vs Honeywell Sensing and Control 3 ...

Page 4

... Series 2 Vane Sensor WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’ ...

Related keywords