Page 1
... Manufacturer) users. Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current draw of only 200 μA, the HIH-4000 Series is often ideally suited for low drain, battery operated systems. Tight sensor interchangeability reduces or eliminates OEM production calibration costs ...
Page 2
... Storage temperature Storage humidity Specific Notes: 1. Can only be achieved with the supplied slope and offset. For HIH-4000-003 and HIH-4000-004 catalog listings only. 2. Device is calibrated at 5 Vdc and 25 ºC. 3. Non-condensing environment. FACTORY CALIBRATION DATA HIH-4000 Sensors may be ordered with a calibration and data printout ...
Page 3
... FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.) FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment.) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% -40 -20 Recommended storage zone 100 Temperature ºC Humidity Sensors 120 140 Honeywell Sensing and Control 3 ...
Page 4
... HIH-4000 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 3 2.5 2 1.5 1 0.5 0 FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 3 2.5 2 1 www.honeywell.com/sensing Relative Humidity (%RH Relative Humidity (%) Sensor Response Sensor Response ...
Page 5
... HIH-4000-002 HIH-4000-004 4,17 [0.164] 8,59 [0.338] 12,70 MIN. [0.50] -ve +ve OUT 3X 0,38 [0.015] 1,27 [0.050] 2,54 [0.100] HIH-4000-001 HIH-4000-003 HIH-4000-005 4,17 [0.164] 1,91 [0.075] +ve -ve OUT 3X 0,38 2,54 ±0,72 2,54 ±0,72 [0.10 ±0.03] [0.10 ±0.03] 5,08 REF. [0.20] Humidity Sensors 2,03 [0 ...
Page 6
... Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP HIH-4000-002 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP HIH-4000-003 Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP, calibration and data printout HIH-4000-004 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP, calibration and data printout ...
Page 7
... THIS PAGE INTENTIONALLY LEFT BLANK. Humidity Sensors Honeywell Sensing and Control 7 ...
Page 8
... In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing ...