91MCE2-P1 Honeywell, 91MCE2-P1 Datasheet - Page 2

no-image

91MCE2-P1

Manufacturer Part Number
91MCE2-P1
Description
Basic / Snap Action / Limit Switches 11N 2.4lb 10A 300VAC 1NO 1NC Dir Opening
Manufacturer
Honeywell
Datasheet

Specifications of 91MCE2-P1

Contact Form
1 NC / 1 NO
Contact Rating
10 Amps
Actuator
Plunger, Roller
Ingress Protection
IP67 / NEMA 1, 4, 12, 13
Operating Force
11 N
Termination Style
Quick Connect
Actuator Type
Roller plunger
Body Style
Compact precision limit switch
Current, Rating
10 Amp (Thermal)
Dielectric Strength
1000 VAC for 1 min between current carrying parts
Ip Rating
IP67; NEMA 1, 4, 12, 13
Mounting Hole Size
Compact precision limit switch. Sturdy die cast housing finished in black paint. IEC 60947-5-1 / EN 90947-5-1 - AC15, A300 and DC13, Q300.
Mounting Type
Screw mount on flat surface or bracket
Number Of Poles
2
Number Of Positions
2
Operation
Snap action
Special Features
Zinc die-cast housing
Termination
1 meter (18 AWG) cable, side exit
Voltage, Rating
300 VAC/250 VDC max.
Sealing
NEMA 1, 4, 12, 13
Global Approvals
cULus, CE, CCC
Operating Temperature
–13°F to +185°F
Electrical Rating
AC15, A300
Mechanical Life
5 Million Operations
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
91MCE Series
TECHNICAL SPECIFICATIONS
ELECTRICAL RATINGS
BAR CHARTS
PIN OUT – “Q” OPTION
Parameter
Operating speed
Operating frequency – mechanical
Operating frequency – electrical
Insulation resistance
Rated voltage
Rated thermal current
Electrical rating
Dielectric strength
Expected mechanical life
Expected electrical life
Operating temperature
Humidity
Cable
Degree of protection
AC15
DC13
Utilization Category
Snap-action for plunger
Designation &
actuators
A300
Q300
Pin 1 & 2 – Normally Closed
125 Vdc
Pin 3 & 4 – Normally Open
120 V
0.55
6
Rated operational current Ie (A) at rated operational voltage Ue
Slow-action for plunger
240 V
0.27
actuators
3
Measure
0,05 mm to 1 m per second
120 ops per minute
30 ops per minute
> 100 Mohm @ 500 Vdc
300 Vac (EN60947-5-1)
10A pre-leaded versions; 3A connector versions
ac 15 A 300; dc 13 Q300
1000 Vac for one minute between current carrying parts
2500 Vac for one minute between non-current carrying parts
5 million operations
5 x 10
-25 °C to 85 °C [ -13 °F to 185 °F] without the formation of ice
< 95 % RH
5 core, 0.75 mm
IP67
IEC 947-5-1 / EN 90947-5-1
5
operations
250 Vdc
380 V
2
Snap-action for side rotary
480 V
500 V
600 V
Slow-action for side rotary
Make
7200
69
VA rating
Break
720
69

Related parts for 91MCE2-P1