G5V-2-H1-DC24 Omron, G5V-2-H1-DC24 Datasheet - Page 4

Low Signal Relays - PCB DPDT PCB 24VDC

G5V-2-H1-DC24

Manufacturer Part Number
G5V-2-H1-DC24
Description
Low Signal Relays - PCB DPDT PCB 24VDC
Manufacturer
Omron
Series
G5V-2r
Datasheet

Specifications of G5V-2-H1-DC24

Coil Current
15 mA
Contact Form
DPDT
Coil Voltage
24 VDC
Coil Type
High Sensitivity
Power Consumption
150 mW
Termination Style
PCB Terminals
Maximum Switching Current
2 A
Contact Rating
0.50 A at 125 VAC, 2 A at 30 VDC
Contact Configuration
DPDT
Coil Voltage Vdc Nom
24V
Coil Resistance
2880ohm
Relay Mounting
PCB
Coil Power Vdc
200mW
Relay Terminals
Through Hole
Contact Voltage Ac Max
125V
Current, Rating
0.5⁄1 AAC⁄ADC
Diameter, Mounting
0.039 in.
Dielectric Rating
500 VAC
Dimensions
0.807 in. L x 0.398 in. W x 0.453 in. H
Function
Sensitive
Material, Contact
Silver
Number Of Pins
8
Power, Rating
62.5⁄24 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, FCC, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-25 °C
Voltage, Control
24 VDC
Voltage, Rating
125 VAC
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
24DC G5V-2-H1

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5V-2-H1-DC24V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G5V-2-H1-DC24V
Quantity:
5 655
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
G5V-2, G5V-2-H1
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog.
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. Be sure to use a
fail-safe circuit design that provides protection against contact failure
or coil burnout.
80
G5V-2
G5V-2-H1
2. Tolerance: ±0.1
3. Orientation marks are indicated as follows:
2. In the interest of product improvement, specifications are subject to change.
Type
Low Signal Relay
DPDT
0.5
20.5 max.
20.3 typ.
Contact form
G5V-2
0.3
3 to 48 VDC
3 to 48 VDC
10.1 max.
9.9 typ.
7.62
Coil rating
3.5
0.5
11.5 max.
11.4 typ.
Terminal Arrangement/
Internal Connections
(Bottom View)
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
16
1
0.6 A at 125 VAC (General Use)
0.6 A at 110 VDC (Resistive)
2 A at 30 VDC (Resistive)
0.5 A at 125 VAC (General Use)
0.2 A at 110 VDC (Resistive)
1 A at 24 VDC (Resistive)
13
4
11
6
9
8
(1.3)
Eight, 1-dia. holes
Contact ratings
7.62
Tolerance: ±0.1
Mounting Holes
(Bottom View)
5.08 5.08
7.62
(1.3)
(1.2)

Related parts for G5V-2-H1-DC24