G6L-1F-DC12 Omron, G6L-1F-DC12 Datasheet - Page 2

Low Signal Relays - PCB LO PROF SPST 12VDC

G6L-1F-DC12

Manufacturer Part Number
G6L-1F-DC12
Description
Low Signal Relays - PCB LO PROF SPST 12VDC
Manufacturer
Omron
Series
G6Lr
Datasheets

Specifications of G6L-1F-DC12

Coil Type
Non-Latching
Coil Current
15 mA
Contact Form
1 Form C
Coil Voltage
12 VDC
Power Consumption
180 mW
Termination Style
Solder Pad
Maximum Switching Current
1 A
Contact Rating
0.3 A at 125 VAC, 1 A at 24 VDC
Contact Configuration
SPST-NO
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Coil Voltage Vdc Nom
12V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
12DC 12DC, G6L-1F G6L1F12DC,

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6L-1F-DC12V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G6L-1F-DC12V
Quantity:
6 888
G6L
Specifications
I
I
Single-side Stable Relays (G6L-1P, G6L-1F)
Note:
I
Note:
Note:
50
Item
Contact mechanism
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Maximum voltage
Power consumption
Item
Contact resistance (See note 1.)
Operating time (See note 2.)
Release time (See note 2.)
Insulation resistance (See note 3.)
Dielectric strength
Impulse withstand
voltage
Vibration resistance
Shock resistance
Endurance
Failure rate (P level) (See note 4.)
Ambient temperature
Ambient humidity
Weight
Contact Ratings
Coil Ratings
Characteristics
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The voltage measurements for operate/release are the values obtained for instantaneous changes in the voltage (rectangular
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking
4. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching
wave).
the dielectric strength.
frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay
suitability under actual load conditions.
Load
Coil and contacts
Contacts of same
polarity
Coil and contacts
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Single crossbar
0.3 A at 125 VAC, 1 A at 24 VDC
1 A
125 VAC, 60 VDC
1 A
3 VDC
60.0 mA
50.0 Ω
75% max. of rated voltage
10% min. of rated voltage
150% of rated voltage
Approx. 180 mW
Classification
Model
Resistive load
100 m Ω max.
5 ms max. (approx. 1.1 ms)
5 ms max. (approx. 0.4 ms)
1,000 M Ω min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
1,500 VAC, 10 × 160 µ s
10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
1,000 m/s
100 m/s
5,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (with a rated load at 1,800 operations/hour)
1 mA at 5 VDC
Operating: -40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 0.6 g
4.5 VDC
40.0 mA
112.5 Ω
2
2
5 VDC
36.0 mA
139.0 Ω
Single-side Stable Relays
G6L-1P, G6L-1F
12 VDC
15.0 mA
800.0 Ω
24 VDC
9.6 mA
2,504.0 Ω
130% of rated
voltage
Approx. 230 mW
G6L

Related parts for G6L-1F-DC12