FTR-H1CA012V Fujitsu, FTR-H1CA012V Datasheet - Page 3

General Purpose / Industrial Relays Low Profile 10A 12V

FTR-H1CA012V

Manufacturer Part Number
FTR-H1CA012V
Description
General Purpose / Industrial Relays Low Profile 10A 12V
Manufacturer
Fujitsu
Datasheet

Specifications of FTR-H1CA012V

Contact Form
SPDT
Coil Voltage
12 VDC
Contact Rating
10 A
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
0.53 W
Contact Material
Gold Plated Silver
Coil Resistance
27 Ohms
Coil Type
1 Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FTR-H1CA012V
Manufacturer:
DIODES
Quantity:
21 000
*
*
*
n SPECIFICATIONS
1
2
3
Contact
Coil
Time Value
Insulation
Life
Other
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load
before production since reference values may vary according to switching frequencies, environmental conditions and ex-
pected reliability levels.
IMQ
IMQ
Arrangement
Material
Style
Resistance (initial)
Rating (Resistive)
Maximum Carrying Current
Maximum Switching Rating
Maximum Switching Voltage
Maximum Switching Current
Minimum Switching Load*
Maximum Inrush Current
Operating Range
Nominal Power (at 20°C)
Operate Power (at 20°C)
Operating Temperature
Operate (at nominal voltage)
Release (at nominal voltage)
Resistance (at 500 VDC)
Dielectric Between open contacts
Strength
Surge Strength*
Mechanical
Electrical
Vibration
Resistance
Shock
Resistance
Weight
Item
Between coil and contacts*
Lamp Load
Contact Rating
Endurance
Misoperation
Misoperation
Endurance
3
1
2
1 form A (SPST-NO), 1 form C (SPDT)
Gold plate silver alloy
Single
Maximum 100 m
10 A 250 VAC/30 VDC
14 A
2,500 VA/300 W
400 VAC 300 VDC
10 A
10 mA 5 VDC
80 to 110 % × V nominal
0.53 W
0.26 W
–40°C to +75°C (no frost) (refer to the CHARACTERISTIC DATA)
Maximum 10 ms
Maximum 5 ms
Minimum 1,000 M
1,000 VAC 1 minute
5,000 VAC 1 minute
10,000 V (at 1.2 x 50 µs)
1 × 10
10 to 55 Hz (double amplitude of 1.65 mm)
10 to 55 Hz (double amplitude of 3.3 mm)
100 m/s
1,000 m/s
Approximately 12 g
2 × 10
Standard Type
5
7
operations minimum
operations minimum
2
(11 ±
2
(6 ±
1
1
ms)
ms)
(at 1 A 6 VDC)
0.4W
0.225W
Sensitive
FTR-H1 SERIES
78 A 120 VAC (at lamp load)
0.53 W
0.26W
2.5 x 10
1 form A (SPST-NO)
TV-5 Rating Type
4
ops. minimum
3