2967620 Phoenix Contact, 2967620 Datasheet - Page 3

no-image

2967620

Manufacturer Part Number
2967620
Description
General Purpose / Industrial Relays PLC-RSC-24DC/21HC RELAY PN 651-2961312
Manufacturer
Phoenix Contact
Series
-r
Datasheets

Specifications of 2967620

Contact Form
SPDT
Coil Voltage
24 V
Contact Rating
6 A at 250 V
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
140 W
Contact Material
Silver Tin Oxide
Coil Current
15.3 mA
Brand/series
PLC-RSC/RSP
Current, Rating
10 A
Dimensions
80 mm L x 14 mm W x 94 mm H
Function
PLC
Material, Contact
AgNi
Phoenix Part Number
PLC-RSC-24DC/21HC
Power, Rating
240 W
Relay Type
Electro Mechanical
Standards
cULus, UL, RoHS
Termination
Screw
Voltage, Control
24 VDC
Voltage, Rating
250 VAC/VDC
Contact Rating (current)
10A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Non Latching
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Operate Time
8ms
Release Time
10ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-40°C ~ 60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
100221_03_en
Output Data
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
Minimum switching current
Maximum shutdown power
Minimum switching power
General Data
Impulse voltage withstand level
Ambient temperature range
Nominal operating mode
Inflammability class according to UL 94 (housing)
Mechanical service life
Air and creepage distances between the circuits
Pollution degree
Surge voltage category
Mounting position
Mounting
Conductor cross-section
Stripping length
Dimensions (W x H x D)
Housing material
Tests/Approvals
CE
UL
GL
Operation
Storage/transport
Screw connection, solid and stranded
Spring-cage connection, solid and stranded
1
2
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
The values in brackets are for connections 12. If connections 12 are bridged, the values in brackets apply.
The PLC-ATP BK insulating plate must be installed for safe isolation between adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500...
is then used for potential bridging.
1
110 V DC
220 V DC
250 V AC
24 V DC
48 V DC
60 V DC
Single contact, SPDT
AgNi
250 V AC/DC
12 V AC/DC
10 A (6 A)
30 A (300 ms)
100 mA
Ohmic load t = 0 ms
240 W (144 W)
58 W
48 W
50 W
80 W
2500 VA (1500 VA)
1.2 W
6 kV
-25°C ... +60°C (230 V type -25°C ... +55°C)
-25°C ... +70°C (230 V type -40°C ... +85°C)
100% operating factor
V0
3 x 10
IEC 60664, IEC 60664 A, DIN VDE 0110, DIN EN 50178/VDE 0106-160,
IEC 60255/DIN VDE 0435
3
III
Any
Can be aligned without spacing
0.14 mm
0.2 mm
8 mm
14 mm x 94 mm x 80 mm
Polybutylene terephthalate PBT non-reinforced, green
c
U u
F
7
2
cycles
2
... 2.5 mm
2
... 2.5 mm
1
2
2
2
2
(26 - 14 AWG)
(26 - 14 AWG)
PHOENIX CONTACT
PLC-R…21HC
3