G6B-2214P-US-DC5 Omron, G6B-2214P-US-DC5 Datasheet - Page 4

General Purpose / Industrial Relays STD DPST-NO 5VDC

G6B-2214P-US-DC5

Manufacturer Part Number
G6B-2214P-US-DC5
Description
General Purpose / Industrial Relays STD DPST-NO 5VDC
Manufacturer
Omron
Series
G6Br

Specifications of G6B-2214P-US-DC5

Coil Resistance
125 Ohms
Contact Form
DPST - NO
Coil Voltage
5 VDC
Contact Rating
5 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
300 mW
Contact Material
Silver Alloy
Coil Current
60 mA
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
5V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
DPST-NO
Current, Rating
5 A
Dielectric Rating
3000 VAC
Function
Power
Mounting Type
PCB
Number Of Pins
6
Power, Rating
1250⁄150 VA⁄W
Standards
UL, CSA, FCC
Termination
Through Hole
Voltage, Control
5 VDC
Voltage, Rating
380 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
5DC G6B-2214P-US G6B2214PUS5DC,

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
G6B-2214P-US-DC5
Quantity:
5 655
Part Number:
G6B-2214P-US-DC5V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G6B-2214P-US-DC5V
Quantity:
20 000
G6B
UL508 (File No. E41643)/CSA C22.2 No.14 (File No. LR31928)
Engineering Data
176
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
G6B-1174P-US
G6B-1174C-US
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
G6B-1114P-US
Maximum Switching Power
G6B-2114P-US, G6B-2214P-US
G6B-2014P-US
Maximum Switching Power
Approved Standards
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC inductive load
(cosφ = 0.4)
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
Switching voltage (V)
Model
AC resistive load
AC resistive
load
SPST-NO
SPST-NO + SPST-NC
DPST-NO
DPST-NC
Endurance
Endurance
Contact form
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-1114P(C)-US
250 VAC/30 VDC
inductive load
(cosφ = 0.4, L/R = 7 ms)
Switching current (A)
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
250 VAC resistive load
30 VDC resistive load
Switching current (A)
G6B-1174P(C)-US
250 VAC/30 VDC
resistive load
3 to 24 VDC
Coil rating
Note: The maximum coil voltage refers
Ambient Temperature vs.
Maximum Coil Voltage
to the maxi-mum value in a
varying range of operating power
voltage, not a continuous voltage.
5 A, 250 VAC (general use)
5 A, 30 VDC (resistive load)
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
5 A, 250 VAC (general use)
5 A, 30 VDC (resistive load)
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Ambient temperature (°C)
Contact rating
G6B-1174P-US
G6B-1114P-US
G6B