G5NB-1A-DC5 Omron, G5NB-1A-DC5 Datasheet

General Purpose / Industrial Relays 3A SPST-NO 5VDC

G5NB-1A-DC5

Manufacturer Part Number
G5NB-1A-DC5
Description
General Purpose / Industrial Relays 3A SPST-NO 5VDC
Manufacturer
Omron
Series
G5NBr
Datasheets

Specifications of G5NB-1A-DC5

Contact Form
SPST - NO
Coil Voltage
5 VDC
Contact Rating
3 A at 125 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
40 mA
Coil Resistance
125 Ohms
Coil Type
Non-Latching
Current, Rating
3 A
Diameter, Mounting
1.1 mm +⁄- 0.1 mm
Dielectric Rating
4000 VAC @ 50⁄60 Hz for 1 Minute Between Coil and Contacts, 750 VAC @ 50⁄60 Hz for 1 Minute Between Contacts of Same Polarity
Dimensions
20.5 mm (Max.) L x 7.2 mm (Max.) W x 15.3 mm (Max.) H
Function
General Purpose
Mounting Type
PCB
Number Of Pins
4
Power, Rating
90 W
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Voltage, Control
5 VDC
Voltage, Rating
380 VAC
Operating Temperature
–40°C to 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5NB1ADC5BYOMZ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5NB-1A-DC5V
Manufacturer:
OMRON
Quantity:
12 000
A Slim Compact Relay with 3 A Switching
Capability and 10-kV Impulse Withstand
Voltage
• Max size 20.5L x 7.2 W x 15.3 W mm.
• Standard models switch up to 3 A
• Low power consumption (200 mW).
• Semi-sealed and sealed types available.
• UL, CSA and VDE approvals.
• RoHS Compliant.
Ordering Information
■ Model Number Legend
1. Number of Poles
2. Contact Form
3. Enclosure Ratings
Application Examples
Water heaters, refrigerators, air conditioners, and small electric appliances
Standard
High Capacity
High-capacity models switch up to 5 A (AC loads only).
PCB Relay
G5NB
1:
A:
None: Flux protection
4:
1 pole
SPST-NO
Sealed
Classification
2
4
4
5
5
G5NB-1A
G5NB-1A-E
Contact Form SPST-NO
Flux-tight model
4. Type
5. Rated Coil Voltage
None: Standard
E:
5, 12, 18, 24 VDC
High Capacity
Enclosure ratings
G5NB-1A4
G5NB-1A4-E
PCB Relay
Sealed model
R
G5NB
C
1

G5NB-1A-DC5 Summary of contents

Page 1

... None: Flux protection 4: Sealed Application Examples Water heaters, refrigerators, air conditioners, and small electric appliances Contact Form SPST-NO Enclosure ratings Flux-tight model G5NB-1A G5NB-1A-E 4. Type None: Standard E: High Capacity 5. Rated Coil Voltage 5, 12, 18, 24 VDC C R Sealed model G5NB-1A4 G5NB-1A4-E G5NB PCB Relay 1 ...

Page 2

... Weight Note: 1. The data shown above are initial value. 2. Measurement conditions: 5 VDC voltage drop method 3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter. 4. This value is for a switching frequency of 120 operations/minute. (P level: λ G5NB 2 PCB Relay 5 VDC 12 VDC 40 ...

Page 3

... A, 125 VAC (resistive) 1.5 A, 250 VAC (resistive) Contact ratings VDC (resistive 125 VAC (resistive) 1.5 A, 220 VAC (resistive 250 VAC (resistive) Electrical Service Life 100 resistive load 250 1,000 Electrical Service Life 125 VAC, 30 VDC resistive load Contact current (A) G5NB PCB Relay 3 ...

Page 4

... Precautions ■ Correct Use Handling Note: 1. The enclosure rating for G5NB-1A and G5NB-1A-E is suitable for flux protection. Do not use immersion-cleaning for these model 2. Do not ultrasonic clean any G5NB relay. G5NB 4 PCB Relay High-capacity models No current 3-A current ...

Page 5

... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. PCB Relay G5NB 5 ...

Page 6

... COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 02/09 Cat. No. J01C-E-01a G5NB 6 PCB Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...