G8P-1C4P-DC24 Omron, G8P-1C4P-DC24 Datasheet - Page 2

General Purpose / Industrial Relays SEALD W/NIB SPDT 24V

G8P-1C4P-DC24

Manufacturer Part Number
G8P-1C4P-DC24
Description
General Purpose / Industrial Relays SEALD W/NIB SPDT 24V
Manufacturer
Omron
Series
G8PTr
Datasheets

Specifications of G8P-1C4P-DC24

Coil Resistance
660 Ohms
Contact Form
SPDT
Coil Voltage
24 VDC
Contact Rating
20 A / 10 A
Contact Termination
Quick Connect
Mounting Style
Through Hole
Power Consumption
900 mW
Contact Material
Silver Cadmium Oxide
Coil Current
36 mA
Coil Type
Non-Latching
Coil Voltage Vdc Nom
24V
Contact Current Max
20A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
28V
Contact Configuration
SPDT
Relay Mounting
PCB
Current, Rating
20 A (NO, NC), 10 A (NC)
Function
Power
Mounting Type
PCB
Number Of Pins
5
Power, Rating
5000 VA⁄560 W (NO), 2500 VA⁄280 W (NC)
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE
Termination
Through Hole
Voltage, Control
24 VDC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
BY DC24 G8P1C4P G8P1C4PDC24BYOMI G8P1C4PDC24BYOMZ OMI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G8P-1C4P-DC24V
Manufacturer:
OMRON
Quantity:
12 000
■ Coil Data
Note: The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of ±10%.
■ Characteristics
Note: 1. Data shown are of initial value. Operate and release times excluding bounce.
■ Characteristic Data
226
5
9
12
24
48
110
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse surge withstand
Vibration
Shock
Ambient temperature
Humidity
Service life
Maximum switching capacity
SPST-NO
voltage
2. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib.
Rated
(VDC)
Rated operating voltage (V)
Power PCB Relay
185
93
77
36
19
9
current
Rated
(mA)
Mechanical durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 2 hours
Malfunction durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 5 minutes
Mechanical durability 1,000 m/s
Malfunction durability 100 m/s
Mechanical
Electrical
27
97
155
660
2,480
12,400
G8PT
resistance
Coil
(Ω)
75% max.
100 mΩ max. (measured with 5 VDC, 1 A)
15 ms. max.
10 ms. max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 minute (coil to contacts),
1,500 VAC, 50/60 Hz for 1 minute (between contacts)
6,000 V between coil to contacts (1.2 μs/50 μs & 100 kHz ring wave per IEC 1000-4-12)
-55° to 105°C, cold coil condition (with no icing)
-55° to 85°C, hot coil condition (hot start) (with no icing)
5% to 85% RH
10 million operations minimum
100,000 operations, 360 ops/hr, at rated load (minimum)
Pick-up
voltage
2
(approx. 10 G)
2
(approx. 100 G)
SPDT
% of rated voltage
10% min.
Dropout
voltage
Rated operating voltage (V)
120% max.
Maximum
voltage
Approx. 900
consumption
Power
(mW)