CA1-DC12V-N Panasonic, CA1-DC12V-N Datasheet - Page 6

General Purpose / Industrial Relays RELAY AUTO 12VDC 1.8MW SCREW MNT

CA1-DC12V-N

Manufacturer Part Number
CA1-DC12V-N
Description
General Purpose / Industrial Relays RELAY AUTO 12VDC 1.8MW SCREW MNT
Manufacturer
Panasonic
Datasheet

Specifications of CA1-DC12V-N

Contact Form
1 Form C
Coil Voltage
12 VDC
Contact Rating
20 A at 12 VDC
Coil Termination
Screw
Contact Termination
Screw
Mounting Style
Screw
Power Consumption
1.8 W
Contact Material
Silver Alloy
Coil Type
With Diode Inside
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7-(2). Electrical life test (Lamp load)
Sample: CA1a-12V-C, 3pcs.
Load: 60Wx4, Inrush current: 110A, steady current: 20A
Halogen lamp actual load
Switching frequency: (ON:OFF = 1s:14s)
Ambient temperature: Room temperature
Load current waveform
Load: Inrush current: 110A, steady current: 20A,
Cautions regarding the protection element
1. Part numbers without protection
elements
1) 12 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 24 V
or higher, or a resistor (680 to 1,000 ).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
2) 24 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 48 V
or higher, or a resistor (2,800 to
4,700 ).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
For Cautions for Use, see Relay Technical Information.
20A
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
200ms
Change of pick-up and drop-out voltage
2. Part numbers with diodes
These relays use a diode in the coil surge
protection element. Therefore, the
release time is slower and the working life
might be shorter compared to part
numbers without protection elements and
part numbers with resistors.
Be sure to use only after evaluating under
actual load conditions.
3. Part numbers with resistors
This part number employs a resistor in
the coil surge protection circuit; therefore,
an external surge protection element is
not required. In particular, when a diode
is connected in parallel with a coil, the
revert time becomes slower which could
adversely affect working life. Please
check the circuit and make sure that a
diode is not connected in parallel with the
coil drive circuit.
10
9
8
7
6
5
4
3
2
1
0
0
Drop-out voltage
No. of operations,
Pick-up voltage
10
10
4
20
Max.
X
Min.
Max.
X
Min.
Change of contact resistance
10
9
8
7
6
5
4
3
2
1
0
0
No. of operations,
10
10
4
20
CA
Max.
Min.
X