ALA2F05 Panasonic, ALA2F05 Datasheet - Page 3

General Purpose / Industrial Relays 3A 5VDC DPST PCB

ALA2F05

Manufacturer Part Number
ALA2F05
Description
General Purpose / Industrial Relays 3A 5VDC DPST PCB
Manufacturer
Panasonic
Datasheet

Specifications of ALA2F05

Contact Form
2 Form A
Coil Voltage
5 VDC
Contact Rating
3 A at 125 VAC
Coil Termination
Solder Pin
Contact Termination
Solder Pin
Mounting Style
Through Hole
Power Consumption
530 mW
Contact Material
Gold Clad Silver Nickel
Coil Type
Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
125V AC
250V AC
LA (ALA)
3-(1). Coil temperature rise
Sample: ALA2F12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 3A
5-(1). Electrical life test
(3 A 125 V AC, resistive load)
Sample: ALA2F12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C
Circuit:
5-(2). Electrical life test
(5 A 250 V AC, resistive load)
Sample: ALA2PF12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C
Circuit:
5-(3). Electrical life test
(UL lamp load test TV-4)
Tested sample: ALA2PF12, 6 pcs.
• Overload test
• Endurance test
Load: 6.0 A 120 V AC (60 Hz),
Inrush: 91 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
Load: 4A 120 V AC (60 Hz),
Inrush: 65 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
G
G
50
45
40
35
30
25
20
15
10
12V DC
12V DC
5
0
0
80
NO
NO
NO
NO
Coil applied voltage, %V
COM
COM
COM
COM
100
68°F
68°F
120
20°C 3A
70°C 3A
70°C 0A
20°C 0A
Contact
welding
detection
and Mis-
contacting
detection
circuit
Contact
welding
detection
and Mis-
contacting
detection
circuit
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
3-(2). Coil temperature rise
Sample: ALA2PF12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 5A
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
100
100
100
50
45
40
35
30
25
20
15
10
80
60
40
20
80
60
40
20
80
60
40
20
5
0
0
0
0
0
0
0
0
80
Drop-out voltage
Drop-out voltage
Drop-out voltage
Pick-up voltage
Coil applied voltage, %V
Pick-up voltage
Pick-up voltage
No. of operations, ×10
No. of operations, ×10
No. of operations, ×10
100
2.5
2.5
120
4
20°C 5A
20°C 0A
70°C 5A
70°C 0A
4
4
2.5
5
5
Max.
Max.
x
Min.
Max.
Min.
x
Min.
Max.
Min.
Max.
x
Min.
Max.
Min.
x
x
x
4. Ambient temperature characteristics and coil
applied voltage
Contact current: ALA2F=3A
ALA2PF=5A
Change of contact resistance
Change of contact resistance
Change of contact resistance
200
150
100
50
50
40
30
20
10
50
40
30
20
10
50
40
30
20
10
0
0
0
0
0
0
0
0
20
Ambient temperature, °C
No. of operations, ×10
No. of operations, ×10
No. of operations, ×10
Allowable ambient temperatures
2.5
2.5
40
against % coil voltages
(max. inside the coil
temperature set as
115°C 239°F)
60
4
4
4
2.5
80
5
5
Max.
x
Min.
Max.
x
Min.
Max.
Min.
x