G5Q-1-DC12 Omron, G5Q-1-DC12 Datasheet - Page 2

General Purpose / Industrial Relays VENTED SPDT 12VDC

G5Q-1-DC12

Manufacturer Part Number
G5Q-1-DC12
Description
General Purpose / Industrial Relays VENTED SPDT 12VDC
Manufacturer
Omron
Series
G5Qr
Datasheet

Specifications of G5Q-1-DC12

Coil Resistance
720 Ohms
Contact Form
SPDT
Coil Voltage
12 VDC
Contact Rating
10 A at 125 VAC (NO), 3 A at 250 VAC (NO), 5 A at 30 VDC (NO)
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
400 mW
Contact Material
Silver Alloy
Coil Current
16.7 mA
Coil Type
Non-Latching
Relay Type
Miniature
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
12DC, G5Q-1 G5Q112DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
G5Q-1-DC12
Quantity:
13 655
Company:
Part Number:
G5Q-1-DC12V
Quantity:
13 655
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial values.
146
Item
Rated load (resistive)
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time
Release time
Insulation resistance (See note 3.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See Note 4)
Ambient temperature
Ambient humidity
2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
4. The electrical life data items shown are possible at 23°C
PCB Relay
G5Q
Mechanical
Electrical
Operating &
storage
Operating &
storage
SPDT
10 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 30 VDC (NC)
Ag alloy
10 A (NO)/3 A (NC)
277 VAC, 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
1250 VA, 150 W (NO)
375 VA, 90 W (NC)
10 mA at 5 VDC (
100 mΩ max.
10 ms max.
5 ms max.
1,000 mΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 × 50 μs) between coil an contacts
Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Destruction: 1000 m/s
Malfunction: 100 m/s
10,000,000 operations (18,000 operations per hour)
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC, resistive load
100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC,
50,000 operations: 10 A at 125 VAC (900 operations per hour)
−40
5% to 85%
°
C to 105°C (-40°F to 221°F) with no icing or condensation
P level: λ
2
5 A (NO)/3 A (NC) at 30 VDC, resistive load
2
(approx. 10G)
(approx. 100G)
60
= 0.1 × 10
−6
/operation)
SPST-NO
10 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC