ACT212 Panasonic, ACT212 Datasheet - Page 4

General Purpose / Industrial Relays 12VDC 1 FORM C X 2 20A 8 TERMINALS

ACT212

Manufacturer Part Number
ACT212
Description
General Purpose / Industrial Relays 12VDC 1 FORM C X 2 20A 8 TERMINALS
Manufacturer
Panasonic
Datasheet

Specifications of ACT212

Contact Form
Dual 1 Form C
Coil Voltage
12 VDC
Contact Rating
20 A at 14 VDC, 10 A at 14 VDC
Coil Termination
Solder Terminal
Contact Termination
Solder Terminal
Mounting Style
Through Hole
Power Consumption
800 mW
Contact Material
Silver Alloy
Coil Current
66.7 mA
Coil Resistance
180 Ohms
Coil Type
Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACT212
Manufacturer:
FREESCALE
Quantity:
560
Part Number:
ACT212
Manufacturer:
Panasonic Electric Works
Quantity:
135
Part Number:
ACT212
Manufacturer:
NAIS
Quantity:
20 000
Part Number:
ACT212 12V
Manufacturer:
PANASONIC
Quantity:
5 400
Part Number:
ACT212-12V
Manufacturer:
NVIS
Quantity:
5 400
Part Number:
ACT212-M41-12V
Manufacturer:
PANASONIC
Quantity:
5 400
Part Number:
ACT212M19-12V
Manufacturer:
NAIS
Quantity:
20 000
CT (ACT)
6-(1). Electrical life test (Motor free)
Sample: ACT212, 3pcs.
Load: 5A steady, Inrush 25A, 14V DC
Brake current: 13A 14V DC,
Power window motor actual load (free condition)
Operating frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Circuit:
Load current waveform
Inrush current: 25A, Steady current: 6A
Brake current: 13A
6-(2). Electrical life test (Motor lock)
Sample: ACT212, 3pcs.
Load: 25A 14V DC
Switching frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Circuit:
Load current waveform
Sample
Sample
M
M
10A
5A
100ms
100ms
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
10
10
8
6
4
2
0
8
6
4
2
0
0
0
Drop-out voltage
Drop-out voltage
Pick-up voltage
Pick-up voltage
No. of operations,
No. of operations,
Contact welding: 0 time
Contact welding: 0 time
10
5
Miscontact: 0 time
Miscontact: 0 time
10
10
4
4
20
10
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
X
X
X
X
Change of contact resistance
Change of contact resistance
50
40
30
20
10
50
40
30
20
10
0
0
0
0
No. of operations,
No. of operations,
10
5
10
10
4
4
20
10
Max.
Min.
X
Max.
X
Min.